AXIS A1001 Network Door Controller
Function
Pin
1
0 V DC (-)
2
DC input
Network Connector
RJ45 Ethernet connector. Use Category 5e cables or higher.
Function
Power and Ethernet
Power Lock Connector
4-pin terminal block for powering one or two locks (DC output). The
lock connector can also be used to power external devices.
Connect locks and loads to the pins according to the hardware pin chart
generated through the hardware configuration.
Function
Pin
1, 3
0 V DC (-)
2, 4
0 V DC,
floating, or
12 V DC
Important
The output circuits in this section are Class 2 power limited.
Notes
For powering controller when not using
Power over Ethernet.
Note: This pin can only be used as
power in.
Specifications
Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3,
44–57 V DC
Max load on outputs = 7.5 W
Notes
For controlling up to two 12 V locks. Use
the hardware pin chart. See Configure
the Hardware on page 41.
26
Specifications
0 V DC
10–30 V DC, max 26 W
Max load on outputs =
14 W
Specifications
0 V DC
12 V DC
Max total load = 500 mA