Axis A1001 Installation Manual page 22

Network door controller
Hide thumbs Also See for A1001:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
AXIS A1001 Network Door Controller
Endurance
Standby Power
Wire Area
NO TICE
NO
NO
TICE
TICE
Each wire shall have an conductor cross-sectional area that corresponds to an conductor
gauge range of AWG 28–16 (CSA) or AWG 22–14 (cUL/UL). Select cables in compliance
with your local regulations.
AWG
28–16
22–14
Connectors
For information about the connectors' positions, see Hardware overview on page 14.
For connection diagrams and information about the hardware pin chart generated through the
hardware configuration, see Connection Diagrams on page 28 and Configure the Hardware on
page 41.
The following section describes the connectors' technical specifications.
Reader Data Connector
6-pin terminal block supporting RS485 and Wiegand protocols for
communication with the reader.
The RS485 ports support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
The Wiegand ports support:
• Two-wire Wiegand
Diameter mm (in)
0.321–1.29 (0.0126–0.0508)
0.644–1.63 (0.0253–0.0641)
IV
I
22
2
Area mm
0.0810–1.31
0.326–2.08