Device Functions Proline Promass 83 FOUNDATION Fieldbus
Endress+Hauser
3.1.2
Function group ADDITIONAL VALUES
MEASURED
⇒
A
VARIABLES
MEASURED VARIABLES → MEASURING VALUES → ADDITIONAL VALUES
TARGET
!
MASS FLOW
This function is not available unless one of the following was selected:
(0020)
• In the DENSITY FUNCTION function (7000):
Use this function to display the currently measured mass flow of the target fluid.
Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
% TARGET
!
MASS FLOW
This function is not available unless one of the following was selected:
(0021)
• In the DENSITY FUNCTION function (7000):
In this function, the currently measured mass flow of the target fluid is displayed as a %
(of the overall mass flow). Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
TARGET
!
VOLUME FLOW
This function is not available unless one of the following was selected:
(0022)
• In the DENSITY FUNCTION function (7000):
In this function, the currently measured volume flow of the target fluid is displayed.
Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
% TARGET
!
VOLUME FLOW
This function is not available unless one of the following was selected:
(0023)
• In the DENSITY FUNCTION function (7000):
Use this function to display the currently measured volume flow of the target fluid as a %
(of the overall volume flow). Target fluid = carried material (e.g. lime powder).
Display:
5-digit floating-point number, including unit and sign
MEASURING VALUES
Function description
Note!
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7021) the option % MASS 2D or % MASS 3D.
Note!
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7021) the option % MASS 2D or % MASS 3D.
Note!
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7010) the option % VOLUME 2D or
% VOLUME 3D.
Note!
– % MASS / % VOLUME
– FLEXIBLE and in the MODE function (7010) the option % VOLUME 2D or
% VOLUME 3D.
3 Block MEASURED VARIABLES
⇒
AAA
MAIN VALUES
⇓
ADDITIONAL VALUES
000
002
11