USB OC (Over Current) protection
(U, R, K, A, B, G, L models)
Cause:
USB power supply is overcurrent.
Normal value:
HIGH (5V)
Detection port: USB_N_OCPRT (FUNCTION (1)
P.C.B. 45 pin of the microprocessor
IC502)
Detected at:
USB_OCPRT (IC309 of DIGITAL
P.C.B.)
THM protection L/Rch
Cause:
Abnormal temperature of heat sink.
Normal value:
A‑S501: 0.20 to 1.80V (AD value: 10‑91)
A‑S301: 0.20 to 1.66V (AD value: 10‑85)
Detection port: THM1 (FUNCTION (1) P.C.B. 84 pin of
the microprocessor IC502)
THM2 (FUNCTION (1) P.C.B. 83 pin of
the microprocessor IC502)
Detected at:
THML (Heat sink temperature detection
Lch IC101 of the MAIN (4) P.C.B.)
THMR (Heat sink temperature detection
Rch IC102 of the MAIN (5) P.C.B.)
Diode THM protection
Cause:
Abnormal temperature of diode (D111
of MAIN (1) P.C.B).
Normal value:
0 to 0.346V (AD value: 0‑18)
Detection port: THM3 (FUNCTION (1) P.C.B. 97 pin of
the microprocessor IC502)
Detected at:
THM3 (TH501 of FUNCTION (4) P.C.B.,
D111 of MAIN (1) P.C.B.)

• Checking of protection information

Check the following information when a protection
function has been activated.
・ Protection history (up to 4)
・ Position of VOLUME knob when the protection
function was activated (*)
・ AD value when the protection function was
activated
・ AD value when the diode THM protection function
was activated
・ Operating information for the speaker relay/
headphones relay
・ AD value for the BALANCE knob
・ Input source information
*
Since the VOLUME knob automatically moves
to the position when the protection function was
activated, do not to operate any other knob while
the VOLUME knob is moving.
USB 過電流プロテクション
原因:
USB 供給電源の過電流。
正常値:
HIGH (5V)
検出ポート: USB_N_OCPRT (FUNCTION (1)
P.C.B.:マイコン IC502 の 45 ピン)
検出先:
USB_OCPRT (DIGITAL P.C.B. の
IC309)
THM(温度)プロテクション L/Rch
原因:
ヒートシンクの温度が異常。
正常値:
A‑S501:0.20 ∼ 1.80V (AD 値:10‑91)
A‑S301:0.20 ∼ 1.66V (AD 値:10‑85)
検出ポート: THM1(FUNCTION (1) P.C.B. マイコン
IC502 の 84 ピン)
THM2(FUNCTION (1) P.C.B.:マイコ
ン IC502 の 83 ピン)
検出先:
THML(MAIN (4) P.C.B. のヒートシン
ク温度検出 Lch IC101)
THMR(MAIN (5) P.C.B. のヒートシン
ク温度検出 Rch IC102)
ダイオード THM(温度)プロテクション
原因:
ダイオード (MAIN (1) の D111)の温度
が異常。
正常値:
0 ∼ 0.346V (AD 値:0‑18)
検出ポート: THM3(FUNCTION (1) P.C.B. マイコン
IC502 の 97 ピン)
検出先:
THM 3(FUNCTION (4) P.C.B. の
TH501、MAIN (1) P.C.B. の D111)
• プロテクション情報の確認
プロテクションが働いた時の下記の情報を確認します。
・ プロテクションの履歴(4つまで)
・ プロテクションが働いた時の VOLUME ツマミの
位置(※)
・ プロテクションが働いた時の AD 値
・ ダイオード THM(温度)プロテクションが働いた
時の AD 値
・ スピーカーリレー/ヘッドホン リレーの動作情報
BALANCE ツマミの AD 値
・ 入力ソースの情報
※ VOLUME ツマミはプロテクションが働いた時の
位置へ自動的に動作するため、動作中にほかのツ
マミを操作しないよう注意してください。