After the Protection Cancel mode is started, the LINE 1
indicator flashes. (Fig. 22)
PS (Power Supply) protection:
If protection function has been activated 3 times
consecutively, the power will not turn on.
I protection L/Rch:
If protection function has been activated 1 time, the
power will not turn on.
*
However, the power turns on when the protection
function worked due to short at the speaker
terminal.
Amplifier DC voltage protection L/Rch:
If protection function has been activated 3 times
consecutively, the power will not turn on.
THM protection L/Rch:
The power turns on no matter how many times the
protection function has worked.
Diode THM protection:
The power turns on no matter how many times the
protection function has worked.
30
プロテクション解除モードでの起動後、 LINE 1 インジ
ケーターが点滅します。 (Fig. 22)
Fig. 22
電源電圧プロテクション:
連続 3 回動作後、電源が入りません。
過電流プロテクション L/Rch:
1 回動作後、電源が入りません。
※ ただし、スピーカー端子のショートでプロテク
ションが働いた場合は、電源が入ります。
アンプ DC 電圧プロテクション L/Rch:
連続 3 回動作後、電源が入りません。
THM(温度)プロテクション L/Rch:
何回動作しても、電源が入ります。
ダイオード THM(温度)プロテクション:
何回動作しても、電源が入ります。