■ POWER AMPLIFIER ADJUSTMENT / パワーアンプ調整
● CONFIRMATION OF IDLING CURRENT
1. Right after power is turned on, confirm that the
voltage across the terminals of R160 (L ch) and
R161 (R ch) are between 0.1 mV and 10 mV.
2. If measured voltage exceeds 10 mV, open (cut
off) R139 (L ch), R142 (R ch) and reconfirm the
voltage.
Attention
If the measured voltage exceeds 10 mV after
repairing the power amplifier, check other parts again
for any possible defect before cutting the resistor.
3. Confirm that the voltage is between 0.2 mV and
15 mV after 60 minutes.
0.1mV–10mV
(L ch)
R160
A-S501
0.1mV–10mV
(R ch)
R161
MAIN (1) P.C.B.
R160
R139
A-S301
● アイドリング電流の調整
1. 電源投入直後、R160(L ch) 、R161(R ch)の端
子間電圧を測定し、0.1 mV から 10 mV の間であ
ることを確認してください。
2. 電圧が 10 mV を超えている場合は、R139( L
ch) 、R142( R ch)をカットし、電圧を再確認し
てください。
注意
パワーアンプ修理後に 10 mV を超えている場合は、
抵抗をカットする前に他に故障箇所が無いかもう一
度調べてください。
3. 60 分後、電圧が 0.2 mV ∼ 15 mV であることを
確認してください。
R139 (L ch)
R142 (R ch)
R161
R142
A-S501/A-S301
Cut off