Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip
(only for cooling and heating unit).
Note:
• After tightening the screw, pull the power cord slightly to check if it is
solid.
• Never cut the power connection wire to extend or shorten the distance.
Step
Six: Pipe arrangement
1. The pipes should be placed along
the wall, bent reasonably and
hidden possibly. Min. semi-
diameter of bending the pipe is
10cm.
2. If the outdoor unit is higher than
the wall hole, you must set a
U-shaped curve in the pipe
before pipe goes into the room, in
order to prevent rain from getting
into the room.
NOTES:
• The through-wall height of drain
hose shouldn't be higher than the
outlet pipe hole of indoor unit.
• The water outlet can't be placed
in water in order to drain smoothly.
The water outlet
can't be placed
in the water
• Slant the drain hose slightly down-
wards; the drain hose can't be
curved, raised, wavy, etc.
The drain hose
can t raise
upwards
.
U-shaped curve
U-shaped curve
Drain hose
drain hose
The drain hose must be straightened
The drain hose can t be wavy
The drain hose
can t be wavy