Main Menu: Auto-Tuning
Adaptation to most all 3 phase induction motors manufactured worldwide is possible with the VS-
616G5's automatic tuning function. Available in both open loop vector and flux vector control modes,
the inverter asks the user for minimal motor information, then guides the user through a quick, simple
tuning process. Below is the motor data required for automatic tuning in the quick-start mode:
Motor Rated Voltage
Motor Rated Current
Motor Rated Frequency
Motor Rated Speed
Number of Motor Poles
Motor Selection
After scrolling through tuning parameters using the ∧ key, depress the Run key to begin auto-tuning.
During tuning, "Tune Proceeding" flashes on the digital operator display. After complete, "Tune Suc-
cessful" is displayed.
Note:
If the Stop key is depressed during tuning, auto-tuning is interrupted and the motor coasts to
stop. The data changed during tuning returns to its original values.
After tuning is complete, depress the Menu key to exit the auto-tuning mode.
VS-616G5 Programming Manual
<ENTER>
Sets motor rated voltage in VAC.
Sets motor rated current in A.
Sets motor rated frequency in Hz.
Sets motor rated speed in rpm.
Sets the number of motor poles.
Chooses connected motor as 1st or 2nd motor.
Section: Auto-Tuning
Auto-Tuning Procedure
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
Q
125