(X)
Location
and l!!'unctlon of Parts
8
REMOTE 1 connectors (female, D-sub 9-pin),
and TERMINATE switch
(BVM-14ElEJ14ElU/14FlE/14FlU/20ElE/
20ElU/20FlE/20FlU)
8
REMOTE 1 connectors (female, D-sub 9-pin),
and TERMINATE switch
(BVM-14ESEl14E5U/l4F5EJ14F5U)
REMOTE 1
"' 11:1111,
REMOTE 1 IN connector
a,
I
TERMINATE
switch
11'.illl-'
REMOTE 1 OUT coonector
These are RS-485 serial interface connectors, used for
connecting two or more BVM-series monitors.
The IN and OUT connectors form a loop-through
connection. Set the TERMINATE switch to OFF
when loop-through is used, to ON when it is not.
Connect two monitors using a straight cable with D-
sub 9-pin plugs such as an RCC-SG (not supplied) as
shown in the figure.
Moritor1
I
---
--
I
:
REMOTE 1
:
: o· :
I
•o
I
I
N
:•
I
I
••
I
I
I
'
.
'
:
TERMINATE
:
I
ONn
:
I
I
:
ourlll.:IL.J..__./
TERMINATE
switch: OFF
Monlt0f2
:
fU:MOTE 1
l
I
~
:
'
I
I
I
I
i
' '
OOT~
i
Ql
9
I
L----------
I
TERMINATE
swllch:ON
Straight cable -
D-sw
9-pln plugs (not
supplied)
Ci)
REMOTE 2 connectors (female, D-sub 9-pin)
(BVM-14ElE/14ElU/14FlE/14FlU/20ElE/
20El U/20FlE/20Fl
U)
8
REMOTE 2 connectors (female, D-sub 9-pin)
(BVM-14E5E/14E5U/14F5E/14F5U)
Forms a pararell switch and controls the monitor
externally. The pin arrangement-and factory setting
function assigned to each pin are given below.
5
1
®O®
9
6
Pin number
Function
1
Set
input' signal channel 1 (numeric keypad
function)
2
Set input signal channel 2 (numeric keypad
function)
3
Select sync signal (SYNC button function)
4
Set
the screen to monochrome, or set for
automatic switching based on the input signal
(MONO button function)
5
Safe area on/off (SAFE AREA button
function)
6, 7
Undefined
8
Tally lamp on/off
9
Ground
All pin function assignments can be changed with the
REMOTE menu.
For information about the REMOTE menu, see "Assigning
the Remote Control Functions -REMOTE Menu".
To switch each func:tion between on and off or
between enable and disable, change pin connections in
the following way.
On or enabled:
Short each pin and pin 9 together.
Off or disabled:
Leave each pin open.
$
ISR (Interactive Status Reporting) connector
(female, D-sub 9-pin)
(BVM-14E1E/14ElU/14FtEJ14FlU/20ElE/
20ElU/20FlE/20FlU)
4!) ISR (Interactive Status Reporting) connector
(remale, D-sub 9-pin)
(BV M-14ESE/14ESU/14F5E/14F5U)
Connect to the JSR system.
Guidance for Basic Monitor Operations
The following table shows how to use a monitor,
control unit and menus to perform basic monitor
operations.
Operations
Monitor/control unit parts
Selecting signals to
be
monitored
Specify the channel number with O to 9
buttons of the numeric keypad.
1 to 90: channel numbers for external
input signals
91 to 95: channel numbers for signals
from the internal testsignal generator
91: PLUGE (Picture line UP Generating
Equipment)
92: 20% gray signal
93: 100% white signal
94: five-step gray scale
95: crosshatch
Remote control
• REMOTE 1 connector
• REMOTE 2 connector
Adjusting the screen and signals
• Function buttons
• MANUAL adjustment buttons and
konbs
Refer lo the operation manual ft>r the
control unit or the built·in control unit
monitor on how to use.
Data transfer
• REMOTE 1 connector
• Monitor memory card
Refer
to
the operation manual for the
rnntrol unit or the built-in t·ontrol unit
numitor on how
to
use.
Menu operations
• Menu operation buttons
• ADDRESS button of the function
buttons
Refer to thr operation manual for the
control unit or the built-in control unit
monitor on how to use.
Menus
• INPUT CONFIGURATION menu
• SYSTEM CONFIGURATION menu
• REMOTE menu
• ADDRESS menu
• CONTROL PRESET ADJ menu
• COLOR TEMP ADJ menu
• ALIGNMENT menu
• ON SCREEN SET menu
• KEY PROTECT menu
• MEMORY CARD menu
•COPY menu