SICK deTem2 Core Operating Instructions Manual

SICK deTem2 Core Operating Instructions Manual

Multiple light beam safety device
Hide thumbs Also See for deTem2 Core:
Table of Contents

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
deTem2 Core
Multiple light beam safety device

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the deTem2 Core and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK deTem2 Core

  • Page 1 O P E R A T I N G I N S T R U C T I O N S deTem2 Core Multiple light beam safety device...
  • Page 2 Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 3: Table Of Contents

    System connection via connection cable (M12, 5-pin to 8-pin).... 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 4 14.7 Mirror columns and device columns............14.7.1 Mirror columns................. 14.7.2 Device columns................ O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 5 List of figures..................63 List of tables..................64 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 6: About This Document

    Chapters not listed here are intended for all target groups. All target groups must understand the safety notes in all of the operating instructions! O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 7: Additional Information

    The LED is flashing. Ö The LED is illuminated continuously. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 8 The symbol indicates the sender. The symbol indicates the receiver. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 9: Safety Information

    8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 10 O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 11: Product Description

    The scanning range is the maximum dimension of the light path between sender and receiver. It depends on the device variant. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 12: Product Characteristics

    Complete overview of the light emitting diode statuses and their meanings: see "Diag‐ nostic LEDs", page O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 13: Receiver Indicators

    Complete overview of the light emitting diode statuses and their meanings: see "Diag‐ nostic LEDs", page 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 14: Example Applications

    Figure 4: Single-sided access protection Figure 5: Multi-sided access protection O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 15: Project Planning

    Information on the individual steps for mounting the device: see "Mounting", page 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 16: Minimum Distance From The Hazardous Point

    For the USA (scope of OSHA and ANSI), different regulations may apply, e.g.: O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 17: Minimum Distance From The Hazardous Point

    (s) 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 18: Minimum Distance From Reflective Surfaces

    Read the minimum distance a in millimeters (mm) in the graph or calculate it based on the respective formula from table O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 19: Protection Against Interference From Systems In Close Proximity To Each Other

    8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 20: Integrating Into The Electrical Control

    In the machine controller, the signals of both OSSDs must be processed sepa‐ rately. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 21: Dual-Channel And Isolated Connection Of Ossd1 And Ossd2

    8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 22: Restart Interlock

    OSSDs are switched off. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 23: Testing Plan

    Define all guidelines for the check. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 24: Test Rod Check

    O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 25: Mounting

    8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 26: Sender And Receiver Must Not Be Installed At 180° Rotated Relative To Each Other

    Figure 13: Sender and receiver must not be installed at 180° rotated relative to each other O P E R A T I N G I N S T R U C T I O N S | deTem2 Core...
  • Page 27: Mounting The Quickfix Bracket

    Select an appropriate screw length to prevent any risk of injury from an overrun. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 28: Mounting The Flexfix Bracket

    A screw nut or threaded hole is required on the machine or profile frame. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 29: Mount Flexfix Brackets To A Profile Frame

    FlexFix brackets that are not being used. Tighten the screws. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 30: Inserting The Multiple Light Beam Safety Device In The Flexfix Brackets

    "Accessories", page O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 31: Mounting The Optional Upgrade Bracket

    To replace a side bracket (part number 2019506): installation version C ° 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 32: Upgrade Bracket, Installation Version A

    2030510 Figure 19: Upgrade bracket, installation version B O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 33: Upgrade Bracket, Installation Version C

    2071021 Figure 20: Upgrade bracket, installation version C 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 34: Electrical Installation

    Prevent the formation of a potential difference between the load and the protec‐ tive device. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 35: System Connection (M12, 5-Pin)

    8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 36: Commissioning

    "Mounting", page 25 • "Electrical installation", page 34 O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 37: Switching On

    Ensure that the multiple light beam safety device can rotate in the bracket. If required, loosen the fixing screws a little. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 38 You have the following adjustment options with the QuickFix bracket: • Adjust vertically (H) O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 39: Quickfix Bracket: Adjust Vertically

    • Adjust vertically (H) • Rotate (± 15°) 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 40: Flexfix Bracket: Adjust Vertically/Rotate

    If the light path is very long, there is a possibility that all four alignment quality light emitting diodes will not light up even when alignment is good. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 41: Check During Commissioning And Modifications

    Carry out the checks according to the instructions from the manufacturer of the machine and from the operating entity. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 42: Operation

    Carry out the checks according to the instructions from the manufacturer of the machine and from the operating entity. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 43: Maintenance

    Make sure that no dispersive media (e.g., dust, fog, or smoke) are within the calcu‐ lated minimum distance from the light beams. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 44: Regular Thorough Check

    Carry out the checks according to the instructions from the manufacturer of the machine and from the operating entity. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 45: Troubleshooting

    If the fault persists, replace the sender, see "Ordering information", page 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 46: Fault Indicator On The Receiver

    19. Switch the voltage supply off and then on again. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 47 "Ordering information", page 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 48: Decommissioning

    We would be pleased to be of assistance on the disposal of this device. Contact us. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core...
  • Page 49: Technical Data

    Maximum permissible conductor resistances must be observed. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 50: Electrical Data

    The supply cable must not be used to connect other loads with the exception of the sender. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core...
  • Page 51: Table Of Weights

    Sender r Receiver Tolerance: ± 50 g 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 52: Dimensional Drawings

    Number of beams S (beam separation) L (length) 1072 O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 53: Ordering Information

    1085566 M2C-SA0340HA10 1085567 M2C-EA03400A10 1085569 M2C-SA0430HA10 1085570 M2C-EA04300A10 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 54: Accessories

    QuickFix bracket Figure 28: Dimensional drawing of the QuickFix bracket (2066048) O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 55: Mounting Accessories

    Mounting accessories Part Part number Alignment tool 4084133 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 56: Weld Spark Guard

    6051946 Ambient operating temperature: down to -30 °C with fixed installation. O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 57: Alignment Aid

    Ambient operating temperature: down to -30 °C with fixed installation. 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 58: Change In Scanning Range Using Deflector Mirrors

    PM3S11-00330030 1040625 1,285 mm 300 mm PM3S13-00430040 1040626 O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 59: Device Columns

    Test rod 30 mm 2022602 Test rod holder 2052249 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 60: Annex

    (part number: see the type label entry in the “Ident. no.” field). O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 61: Note On Specified Standards

    ISO 13849-1 GB/T 16855.1 ISO 13855 GB/T 19876 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 62: Checklist For Initial Commissioning And Commissioning

    O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK...
  • Page 63: List Of Figures

    29. Dimensional drawing of the upgrade bracket (2071021)........55 30. Mounting the weld spark guard................. 56 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 64: List Of Tables

    27. Ordering information, test rods..................59 28. Note on specified standards..................61 O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 65 LIST OF TABLES 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 66 LIST OF TABLES O P E R A T I N G I N S T R U C T I O N S | deTem2 Core 8014304/ZKD8/2017-03-23 | SICK Subject to change without notice...
  • Page 67 LIST OF TABLES 8014304/ZKD8/2017-03-23 | SICK O P E R A T I N G I N S T R U C T I O N S | deTem2 Core Subject to change without notice...
  • Page 68 Phone +36 1 371 2680 Phone +386 591 788 49 E-Mail office@sick.hu E-Mail office@sick.si India South Africa Phone +91 22 4033 8333 Phone +27 11 472 3733 Further locations at www.sick.com E-Mail info@sick-india.com E-Mail info@sickautomation.co.za SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents