Section 5. Troubleshooting; Using The Information Led - Zodiac CX35 Owner's Manual

Robotic pool cleaner type em14, type em15
Table of Contents

Advertisement

Section 5. Troubleshooting

5.1

Using the Information LED

The information LED
cleaner malfunctions.
LED Flashing
1 Flash
Floating cable may not be plugged
LED flashes once
into the Control box correctly.
2 Flashes
Cleaner wheels may be jammed
LED flashes twice
or brushes may be blocked with
debris.
3 Flashes
Pump axis or propeller may be
LED flashes three
jammed with debris.
Dirty filter.
on the Control box flashes in a specific sequence to indicate one of three possible
Cause
Solution
Unplug the floating cable from the
Control box and reconnect.
If the problem persists, contact
Zodiac Customer Service at
1300 763 021
Turn cleaner wheels to ensure
they are not jammed.
Check brushes for debris.
Start a new cleaning cycle.
If the problem persists, contact
Zodiac Customer Service at
1300 763 021.
Check the pump axis for debris.
Check propeller for debris.
Clean the filter.
Start a new cleaning cycle.
If the problem persists, contact
Zodiac Customer Service at
1300 763 021.
H0574000_REVA