Fujitsu AUXB04GALH Service Manual page 253

Airstage j-iiil series
Hide thumbs Also See for AUXB04GALH:
Table of Contents

Advertisement

Thermistor (Discharge)
Thermistor (Comp.temp.)
HEATER (CRANK CASE)
Remove the COMP BOLTs.
(4 places)
Heat up the brazed part of
the discharge side and disconnect.
Caution
There is a possibility of catching fire to oil when removing by the welding.
Procedure for compressor installation.
Reverse procedure to removing the compressor.
Precautions for installation of Compressor.
(1) When brazing, do not apply the flame to the terminal.
(2) When brazing, be sure to replace the air in the pipe with nitrogen gas to prevent forming oxidization scale.
Thermistor (Discharge)
Cut the binders. (2 place)
Thermistor (Comp.temp.)
Remove the Thermistor
(Comp.temp)
Discharge side
Heat up the brazed part of the suction side and disconnect.
Remove the COMPRESSOR.
06-13
Remove the Thermistor clip and
Thermistor(Discharge).
HEATER (CRANK CASE)
Hook
Remove the HEATER.
(CRANK CASE)
Suction side

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auxb07gaxh seriesAuxb18gaxh seriesAuxb24gaxh seriesAuxd18gaxh seriesAuxd24gaxhseriesAuxa18galh ... Show all