Fujitsu AUXB04GALH Service Manual page 105

Airstage j-iiil series
Hide thumbs Also See for AUXB04GALH:
Table of Contents

Advertisement

Trouble shooting 27
INDOOR UNIT Error Method:
Coil 1 (2)* Expansion valve Error
Detective Actuators:
Indoor unit controller PCB
Forecast of Cause :
1. EEV1 coil lose connection
4. Controller PCB (DC 12V) output abnormal
5. Noise momentary open, voltage drop
Check Point 1 : Check the connection of EEV1 (2)* connector
Check If the connector CN10 (CN11)* is lose connection or not
OK
Check Point 2 : Check the EEV1 (2)* wire
Check if the wire of EEV1 (2)* has damege or not
(Slash, Braking of wire, Pinching, etc. )
OK
Check Point 3 : Check the EEV1 (2)* Coil
Check if the circuit of EEV coil winding is good or not
(Refer to the service parts Information 8 )
OK
Check Point 4 : Check the output of EEV1 (2)* on the Main PCB
Check if the DC 12 is on between the pin No.1 of CN10 (CN11)* and
GND : Pin No.6 of CNB01 (Pin No.7 of CNB01)*
(Disconnect the wire of EEV1 (2)* when you check the output of EEV1 (2)*)
OK
Check Point 5 : Noise, momentary open, voltage drop
Check if temporary voltage drop was not generated.
Check if momentary open was not generated.
Check if ground is connection correctly
or there are no related cables near the power line.
E52. 1
Indicate or Display:
Outdoor Unit : E.5U.1
(E52. 2)*
Indoor Unit
: Operation LED 5 times Flash, Timer LED 2 Times Flash,
Error Code
Detective details:
When the EEV1 (2)* drive circuit is open circuit
2. EEV1 (2)* wire(s) cut or pinched
04-35
Filter LED Continuous Flash.
: 5 2
Replace EEV1 (2)*coil
NG
Replace EEV1 (2)* coil
NG
Replace Main PCB
NG
( )*: for DX-Kit System
3. Defective EEV1 (2)* coil

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auxb07gaxh seriesAuxb18gaxh seriesAuxb24gaxh seriesAuxd18gaxh seriesAuxd24gaxhseriesAuxa18galh ... Show all