TROUBLESHOOTING
For ease of service,
the systems
are equipped
with diagnostic
code
display
LEDs
on both the indoor
and outdoor
units.
The outdoor
diagnostic
display
is an LED
on the outdoor
unit board
and is
limited
to very
few errors.
However,
it is useful
in identifying
special
error codes like a failure
of the outdoor
coil sensor
on heat
pumps.
The indoor
diagnostic
display
is a combination
of flashing
LEDs
on the display
panel
or the front of the unit.
If possible,
always
check
the diagnostic
codes
displayed
on the indoor
unit
first.
The diagnostic
codes for the indoor
and outdoor
units are listed in
the tables below.
INDOOR UNIT DIAGNOSTIC
GUIDES
9K & 12K Units
Operation
Timer
Lamp
Lamp
Failure Mode
€_
X
Indoor fan speed has been out of control for over 1 minute
€_
On
Indoor room temp. or evaporator sensor is open circuit or short circuited
X
€_
Compressor
over-current
protection has been activated four times
On
€_
EEROM error
€_
€_
Indoor unit communication
error
(Illuminates simultaneously)
18K & 24K Units
Operation
Timer
Defrosting
Auto
Lamp
Lamp
Lamp
Lamp
Failure Mode
€_
€_
€_
€_
Over-current
protection of the compressor
occurs four times
X
€_
X
X
Indoor room temp. sensor is open circuit or short circuited
€_
X
X
X
Temp. sensor on indoor evaporator
is open circuit or short circuited
X
X
€_
X
Temp. sensor on outdoor condenser is open circuit or short circuited (not cooling
only modes)
X
X
€_
€_
Outdoor unit protects (outdoor temp. sensor, phase order, etc.)
X
€_
X
€_
EEROM error
X
X
X
€_
Indoor unit communication
error
€_
= Flashing
X = Off
For additional
diagnostic
information,
refer to the Service Manual.
Infrared
signal
receptor
/
OPERATION
AUTO
TIMER
0
0
0
ECON
PRE-DEF
o
o
o
HP Model
size 009
Infrared
signal
receptor
/
A07544
HP Model
size 012
* PRE-DEF
light will illuminate
when
the unit is running
in FAN
ONLY
mode
on Cooling
Only
units.
Note:
Cooling
only units
have
same
LED
lights
but without
PRE-DEF
print.
Fig. 21 -
LED
Display
Panel
AUTO
TIMER PRE.-DEF* OPERATION
A08483
HP Model
size 018-024
OUTDOOR
UNIT
DIAGNOSTIC
GUIDES
Flashing
Diagnostic
Times after 2
Failure Mode
Second Off
Chart
5
Communication
failure
4 or 6
2
Condenser temperature sensor failure
2
1
Other indoor failure
If the unit is operating
normally,
the LED light on the outdoor
board is lit continuously.
If there is a failure, the LED light will flash a specific
number
of times.
Refer to the Outdoor
Unit Diagnostic
table above to determine
failure.
13