START-UP
Test Operation
Perform
test operation
after completing
gas
leak and
electrical
safety check.
(See Fig., 20)
t
[ ...........................................................................................
J
_AUTO/COOL
Manual Button
/
A07363
Fig. 21) -
Test Operation
1. Push the "ON/OFF"
button on Remote Control to begin
testing.
NOTE:
A protection feature prevents air conditioner from being
activated for approximately 3 nfinutes.
2. Push MODE button, select COOLING,
HEATING, FAN
mode to check if all functions work correctly.
3. When ambient temperature is lower than 63°F/17°C,
the
unit cannot be controlled by Remote Control to run in cool-
ing mode. For this condition, manual operation must be
used.
(1.) Open front panel of the indoor unit;
(2.) Push the manual switch once to energize the unit.
4. Be sure to set manual switch to "OFF"
(by pushing it
twice) after finishing test operation.
NOTE:
For Heat Pumps, follow the same procedure.
SYSTEM
CHECKS
1. Conceal
the tubing
where possible.
2. Make sure that the drain tube slopes downward
along its en-
tire length.
3. Ensure
all tubing
and connections
are properly
insulated.
4. Fasten tubes to the outside
wall, when possible.
5. Seal the hole through
which
the cables
and tubing pass.
INDOOR
UNIT
1. Do all Remote
Control
buttons
function
properly?
2. Do the display
panel lights work properly?
3. Does the air deflection
louver function
properly?
4. Does the drain work?
OUTDOOR
UNIT
1. Are there unusual
noises
or vibrations
during
operation?
Explain
Following
Items
To Customer
With
The Aid
Of The
Owner's
Manual:
1. How
to
turn
air
conditioner
on
and
off;
selecting
COOLING,
HEATING
and other
operating
modes;
setting
a desired temperature;
setting the timer to automatically
start
and stop air conditioner
operation;
and all other features
of
the Remote
Control
and display
panel.
2. How to remove
and clean the air filter.
3. How to set air deflection
louver.
4. Explain
care and maintenance.
5. Present
the Owner's
Manual
and installation
instructions
to
customer.
12