Configuring Link Monitoring; Configuring Errored Symbol Event Detection - HP 5900 Series Configuration Manual

High availability configuration guide
Hide thumbs Also See for 5900 Series:
Table of Contents

Advertisement

connection. If an Ethernet OAM entity receives no Information OAMPDU within the Ethernet OAM
connection timeout time, the Ethernet OAM connection is considered disconnected.
By adjusting the handshake packet transmission interval and the connection timeout timer, you can
change the detection time resolution for Ethernet OAM connections.
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
After the timeout timer of an Ethernet OAM connection expires, the local OAM entity ages out its
connection with the peer OAM entity, causing the OAM connection to disconnect. To keep the Ethernet
OAM connections stable, HP recommends that you set the connection timeout timer to be at least five
times the handshake packet transmission interval.
To configure the Ethernet OAM connection detection timers globally:
Step
1.
Enter system view.
2.
Configure the Ethernet OAM
handshake packet
transmission interval.
3.
Configure the Ethernet OAM
connection timeout timer.
To configure the Ethernet OAM connection detection timers on a port:
Step
1.
Enter system view.
2.
Enter Layer 2/Layer 3 Ethernet
port view.
3.
Configure the Ethernet OAM
handshake packet
transmission interval.
4.
Configure the Ethernet OAM
connection timeout timer.

Configuring link monitoring

After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section automatically take effect on all Ethernet ports.

Configuring errored symbol event detection

An errored symbol event occurs when the number of detected symbol errors in the detection window
(specified number of received symbols) exceeds the predefined threshold.
You can configure this command in system view or port view. The configuration in system view takes effect
on all ports, and the configuration in port view takes effect on the specified port. For a port, the
configuration in port view takes precedence.
Command
System-view
oam global timer hello interval
oam global timer keepalive
interval
Command
System-view
interface interface-type
interface-number
oam timer hello interval
oam timer keepalive interval
5
Remarks
N/A
The default is 1000 milliseconds.
The default is 5000 milliseconds.
Remarks
N/A
N/A
By default, an interface uses the
value configured globally.
By default, an interface uses the
value configured globally.