Configuring Bfd For The Vrrp Master To Monitor The Uplinks - HP 5900 Series Configuration Manual

High availability configuration guide
Hide thumbs Also See for 5900 Series:
Table of Contents

Advertisement

# Enable VRRP state debugging and BFD event debugging on Switch B.
<SwitchB> terminal debugging
<SwitchB> terminal monitor
<SwitchB> debugging vrrp fsm
<SwitchB> debugging bfd event
# When Switch A fails, the following output is displayed on Switch B.
*Dec 17 14:44:34:142 2013 SwitchB BFD/7/EVENT:Send sess-down Msg,
[Src:192.168.0.102,Dst:192.168.0.101,Vlan-interface2,Echo], instance:0, protocol:Track
*Dec 17 14:44:34:144 2013 SwitchB VRRP4/7/FSM:
IPv4 Vlan-interface2 | Virtual Router 1 : Backup --> Master
tracked object changed
# Display detailed information about the VRRP group on Switch B.
<SwitchB> display vrrp verbose
IPv4 Virtual Router Information:
Running Mode
Total number of virtual routers : 1
Interface Vlan-interface2
VRID
Admin Status
Config Pri
Preempt Mode
Auth Type
Virtual IP
Virtual MAC
Master IP
VRRP Track Information:
Track Object
The output shows that when BFD detects that Switch A fails, the Track module notifies VRRP to change the
status of Switch B to master. The backup can quickly preempt as the master without waiting for a period
three times the advertisement interval plus the Skew_Time.

Configuring BFD for the VRRP master to monitor the uplinks

Network requirements
As shown in
Switch A and Switch B belong to VRRP group 1. The virtual IP address of VRRP group 1 is
192.168.0.10.
The default gateway of the hosts in the LAN is 192.168.0.10.
Configure VRRP-Track-BFD collaboration to monitor the uplink on the master and meet the following
requirements:
When Switch A operates correctly, the hosts in the LAN access the Internet through Switch A.
When Switch A detects that the uplink is down through BFD, Switch B can preempt as the master.
The hosts in the LAN can access the Internet through Switch B.
: Standard
: 1
: Up
: 100
: Yes
: None
: 192.168.0.10
: 0000-5e00-0101
: 192.168.0.102
: 1
Figure
35:
Adver Timer
: 100
State
: Master
Running Pri
: 100
Delay Time
: 0
State : Negative
140
reason: The status of the
Switchover

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5920 series

Table of Contents