Measuring Frequence
1.
Set the function switch to the Hz position.
2.
Insert the black test lead banana plug into the negative
(COM) jack
3.
Insert the red test lead banana plug into the
V/Hz%/ /Cap/°C jack.
4.
Touch the test probe tips to the circuit under test.
5.
Read the frequency in the display.
6.
The digital reading will indicate the proper decimal point,
symbols (Hz,kHz, MHz) and value.
Measuring Resistance
1. Set the function switch to the green
2. Insert the black test lead banana plug into the negative
COM jack.
Insert the red test lead banana plug into the
V/Hz%/ /Cap/°C jack.
3. Indicate "OL" "M:"on the display.
4. Touch the test probe tips across the circuit or part under
test. It is best to disconnect one side of the part under
test so the rest of the circuit will not interfere with the
resistance reading.
5. Read the resistance in the display.
19