M2M Easy 2 Installation Manual

Security communicator
Hide thumbs Also See for Easy 2:
Table of Contents

Advertisement

M2M Easy 2
Security Communicator
®

Installation Guide

for firmware v2.1 R08
_____________________________________
Rev: 2.2
2017-02-09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Easy 2 and is the answer not in the manual?

Questions and answers

Summary of Contents for M2M Easy 2

  • Page 1: Installation Guide

    M2M Easy 2 Security Communicator ® Installation Guide for firmware v2.1 R08 _____________________________________ Rev: 2.2 2017-02-09...
  • Page 2 Document specifications This documentation was compiled for the M2M Easy 2 Security Communicator with the ® WM Systems LLC. SW v2.1 R08 or newer versions, which were developed by , and contains the step-by-step description of its installation, the program update process and the detailed introduction of the setup parameters necessary for its operation.
  • Page 3: Table Of Contents

    4.10 Manual arming ........................34 4.11 Gate opening ........................34 4.12 Disabling zones (Bypass mode) ..................35 Configuring the Easy 2 ................37 5.1 GSM transmitter settings...................... 37 5.2 Transmitting to Enigma IP-receiver (Settings) ................ 39 5.3 GPRS transmitting settings ....................43 5.4 Standalone Alarm System mode settings ................
  • Page 4 Further information about operation of the Easy 2 ........70 6.1 Primary and secondary communication channel ..............70 6.2 Using the secondary channel ....................70 6.3 Signalling by GSM call ......................71 6.4 Receiving the signalling of events ..................71 6.5 Life signals .........................
  • Page 5: Connecting The Ports

    7 – ALR: Alarm line (TIP RING input (for alarm center analogue phone line connection) 8 – PROG: RJ11 connector (for configuration, software upload) for RJ11-RS232 cable Easy 2 IO 9 – Expansion board connector (used in case of applying the...
  • Page 6: Wiring

    1.2 Wiring Preparation  Take the 4 spacer fixing tabs provided with the device, and place them into the PCB holes as shown in the picture. Prepare a screwdriver, the 2 terminal blocks provided with the device, and the stripped wire pair necessary for connection, with appropriate distinctive colors (power connector –...
  • Page 7 In voltage input operation mode, the input lines can be activated with 5-24V DC voltage, in opposite way these are inactive. EasyTerm The proper operation mode can be configured as well with the application. INPUTS OUTPUT (IN1, IN2) (OUT) These can be configured seperately to operate as a voltage or contact mode for the input. These settings can be setup with the jumpers besides the terminal blocks of the input lines –...
  • Page 8  Input low signal level: 0-1V  Current in active status (for the Easy 2 inputs): 0.3-3mA  Current in active status (for the further Easy 2 IO inputs): 1-12mA Easy 2 IO In case of using the -expander board, further 6 pcs of inputs are available (IN3..IN8), which has the same operation and configuration possibility as listed here above.
  • Page 9 When activating the output, the ALR LED – beside the output - indicates the active (closed) position with the appropriate color/light - during the operation. Inserting the M2M Easy 2 IO board (optional)  M2M Easy 2 Security Communicator ®...
  • Page 10: Led Signals

    Connecting the power supply  The 8-24V power-supply voltage (typically 12V power adapter, or 24V power supply) can be connected to the PWR input through a wire pair. When connecting the power, the device will be immediately started to operating, when the PWR LED will indicate it with the appropriate color/light.
  • Page 11 Filure codes – for signing the device opreation troubles – in case of a failure, read the Chapter nr. 9!  1 flash - Module failure Easy 2 The serial connection is not operating properly between the module and the board. After 1 minute, the device automatically tries to restart the module.
  • Page 12  2 flashing - SIM card failure Possible reasons: o there is no SIM card inserted o SIM card pinpad contact error The device in this status will not continues its initialization, the receiving of serial port commands is still active (for parametrizing). After 1 minute, the device automatically tries to restart the module.
  • Page 13  6 blinkings – the device is registered to the GPRS network, it has an IP address, but cannot login to the server Possible reason: the primary and the secondary server is not available/accessable Visible sympthoms:  the opening of the TCP/UDP port was not succesful (e.g. wrong server settings applied), ...
  • Page 14: Operation Requirements

    Ring). Lights: speaker pulled on, not lights: speaker put down or alarm center not presented. PWR: Power voltage active - green Easy 2 Signs when the is under power and voltage and operating. When it has no light, the Easy2 is powered off and has no active power source.
  • Page 15 Windows XP/Vista/Win7 operation system and .Net 4.0 framework. Microsoft link: https://www.microsoft.com/en-us/download/details.aspx?id=53344 EasyTerm Downloading the ® configurator application from our website, at the  Downloads / M2M Easy 2 Security Communicator product: Win7/Win8/Win10 version: http://www.m2mserver.com/m2m-downloads/EasyTerm_v1_3_1_EN.ZIP WinXP version: http://www.m2mserver.com/m2m-downloads/EasyTerm_v1_3_1_XP_EN.ZIP M2M Easy 2 Security Communicator ®...
  • Page 16: Installation Of The Device

    The SIM card must be inserted or removed only turned status of the Easy 2 device! For inserting the SIM-card slide the card (provided by the Mobile Operator) into the metal SIM card bay at...
  • Page 17: Turning On The Device

    When the power line will be removed or the power supply will be disconnected, the device will be turned off. 2.2 Turning on the device Easy 2, After starting the it is required ca. 40-60 seconds from the startup to the complete operation (succesful GSM/GPRS communication, etc.), which will be signed by the status LEDs...
  • Page 18 When you will notice a different operation of the device, check the Problem troubleshooting part of the Chapter nr. 9! When your device was already installed, check the current firmware version of the EasyTerm device (SWVER value in the application). When the version is not V2.1 R08 or newer (e.g.
  • Page 19: Connecting The Device To A Computer

    Support/Downloads menu: http://www.m2mserver.com/en/support Security alarm transmitters Download the following files ( part in the list), then uncompress the files:  Easy 2 Security Communicator EasyTerm configuration application (v1.3.1) File EasyTerm_v1_3_1_EN.ZIP Contains:  EasyTerm – for software updates, parameter configuration: Terminal- and configurator tool, which can be used for firmware refresh and programming the device.
  • Page 20: Connecting With A Computer

    Easy 2 installation of the driver is necessary for accessing the It is important that at this point neither the Easy 2 device, nor the USB connector must NOT be connected to the computer! On your computer, at the Control Panel / System / Device Manager check that the driver has been installed properly.
  • Page 21: Easyterm (Configuration, Software Refresh)

    (configuration, software refresh) 4.1 Introducing the EasyTerm tool The device is shipped with factory firmware and configuration. Easy 2 By default – without any chonfiguration changes – the is operating as a GSM transmitter (therefore, it will forward the incoming signals of the Tip-Ring connected alarm system through the GSM network - with CID codes –...
  • Page 22: Connecting To The Device

    Password, and monitorize the serial port through the terminal at Serial Monitoring tab. Attention! By factory default the Easy 2 is configured for transmitting the incoming alarm signals of the connected alarm system through GSM connection! When you would like to use the device as a GPRS-transmitter or as a standalone alarm system or any other proposal, then take consider the value Address and Port number when setup and connect to the device.
  • Page 23 b.) Connecting through TCP IP (remotely) Connection window In the (1) at the TCP-IP tab you will found the necessary IP settings for the GPRS connection. Device IP Fill the SIM card IP address to the (get the information from your mobile service provider).
  • Page 24 During this time, the device transmits the life signal and signal strength values frequently, according to the settings. When connecting to the GSM or Easy 2 GPRS network, the checks the filled PIN code and will assign that the password was accepter or not.
  • Page 25: Status And Device Data

    Easy 2 ABCD Then the password will be restored and recovered to the default value. Monitoring the serial port messages: At the 4th tab, at the Serial Monitoring, you can Open it, and connect to the device in surveillance (read only) mode, when only the left side of the window is active with the signal strength data and terminal window messages.
  • Page 26: Terminal Window, Communication Messages

    At the ARM title you can see the ON/OFF status of the status – in case of standalone alarm system mode only! – that the alarming is currently turned ON or OFF. With these buttons you can Easy 2 also control the alarming status: ON-arm, OFF-disarm the alarm status of the alarm system.
  • Page 27 You can filter the listed parameters with the Param. group. Therefore you can list and modify only the interesting, related parameters. Easy 2 Attention! The configuration of the device is empty by general! If you are attempted to use the device at the very first time, then let’s open the configuration file...
  • Page 28: Contact List For Output Control And Gate Opening

    By the Select all button you can choose (mark) all parameters or Deselect All (unmark). This will help you later to write/read the marked parameters to the device. Attention! When you were modified a parameter value, the device will not notified from the Easy2 change, while you will send the parameter value to the ! For this you have to mark...
  • Page 29 You can define phone call numbers– max. 125 – which are allowed to remotely control the output line – or the connected device or gate opening system. The device will be control its output line only due to the received command SMS text messages – or ringings - of the listed numbers! This feature is very useful for hotels parking houses, companies, condominiums.
  • Page 30: Firmware Upload/Refresh

    Important! Over the manual control, these features can be remotely controlled via SMS text messages and initiating a voice call (ringing). 4.7 Firmware upload/refresh Easy 2 When you are attempted to upload a newer software to the then choose the Firmware...
  • Page 31 Easy 2 automatically handle it. During a TCP/IP firmware refresh the will send installation progress CID codes. In case of firmware upload from the serial port, Browse the required firmware binary file (the filename contains the software version – e.g. EASY2_V21R08.bin – means version 2.1, R08 = relase nr.
  • Page 32 The EasyTerm program window will not answers for any intervention or action during the upload. Do not change the focus from the program! During the refresh method, the device has only a limited functionality. It does not receives signals of the alarm system, does not transmits the incomin input signal changes and events, does not sends life signals and does not process the incoming SMS messages! During the installation you can see the „Sending file..
  • Page 33: Device Restart

    At the and of the process, the device will restart and disconnected from the serial port connection. 4.8 Device restart Easy 2 If you are attempted to restart the , then click on the right-side Restart device button at the bottom of the screen.
  • Page 34: Manual Arming

    Anyway, it is possilble to remotely control the Easy2 arming through SMS messages. 4.11 Gate opening Easy 2 EasyTerm output can also be manually controlled with the . When the output was GATE configured (OUTMODE parameter) to...
  • Page 35: Disabling Zones (Bypass Mode)

    At the right top side of the screen you will found the Bypass tab. When opening, you can drop- down a list and choose the Easy 2 inputs item. Regarding the choice, the program reads out the input information of the related zones, parameters, life signals. The reading process is assigned by the progress bar.
  • Page 36 button to turn the bypass on (turns off the alarming for the zone) or turn OFF the bypass for it (turns on the current zone alarming). The zone bypass enabling is also possible through SMS commands by text messages – see later.
  • Page 37: Configuring The Easy 2

    5. Configuring the Easy 2 The device is capable for using and operating for the following type of tasks. Then you will found the main important configuration options for the listed operation modes, using the Easy2 1. GSM transmitter (pre-configured to this mode, by default): the alarm...
  • Page 38 GSM transmitter settings Load the factory default .CFG file by the Browse button. Device Type Choose the GPRS Settings parameter group at the . Then the program will load the related parameters. Disabled Check that the GPRSEN value is , which means that the device operating as a GSM transmitter.
  • Page 39: Transmitting To Enigma Ip-Receiver (Settings)

    Easy 2 OBJ_ID parameter, you can request that the overwrite the incoming event’s Contact ID code – incoming on TIP-RING line from the alarm system - Customer ID by its own (ACCOUNT parameter). If you’ll enable it, then this will be transmitted to the center by this identifier.
  • Page 40 Device Type Choose the GPRS Settings parameter group at the . Then the program will load the related parameters. Change the GPRSEN value to Enable status for the GPRS transmitting. At the SFUNCT parameter you can define thath the primary or secondary server IP address will be the first in the signalling sequence.
  • Page 41 of the parameter sending, the device is restarting by using the new settings. GPRS service and APN settings Device Type Then, let’s opent the GPRS Service parameter group at the for the settings . Then the program will load the related parameters. At the value, you have to define the APN name for the SIM-card related GPRS data package service.
  • Page 42 Device Type view at the . Then the program will load the related parameters. Easy 2 All detected and received signals and events of the input lines are stored in a puffer with their timestamps, where 32 events can be stored temporary by the system. These will...
  • Page 43: Gprs Transmitting Settings

    Fo further settings, please check the chapter 5.6. 5.3 GPRS transmitting settings Easy 2 In this operation mode the is transmitting to the dispatcher center’s IP address or to the remot dispatching software - through GPRS. The further settings are recommended to check or modify in case of necessary.
  • Page 44 BACKUP parameter allows a backup signalling to the centre through GSM - in case of mobile network fall/outage. The GSM-relevant parameters must be also configured – e.g. SYS1. You can modify the ACCOUNT parameter value if you are attempted to signalling an own customer ID for the identification.
  • Page 45 At the end of the parameter sending, the device is restarting by using the new settings. Input line’s Contact ID settings Easy 2 All detected and received signals and events of the input lines are stored in a puffer with their timestamps, where 32 events can be stored temporary by the system.
  • Page 46 In case of unsuccessful sending (e.g. outage or fall of the primary IP address or a network trouble), then after some delay it retries to send. If it is also unsuccessful, then it tries to send the events to the secondary IP address. It it will not success then it drops the event. (In case of a voice call the whole event sequence will be transmitted during a call.) configuring the input line’s event transmitting let’s open the GPRS Input Parameters...
  • Page 47 On the input lines of the device it is capable of generating Contact ID messages and transmitting them by the ascending edge (L→H) and descending (H→L) edge. (The number of the current input is signed here by’x’). The length of the time frame can be configured by the IDELAY in 20 msec steps, which is enabled...
  • Page 48 If you’ve changed one of the listed parameter values, then the program will highlight the changed value lines by bold. For sending the listed parameter values for the device Selected (regarding the coloumn) – check the proper selection – push the Write config button at the bottom of the screen.
  • Page 49 is operating quite similar, but it is useful for ring notification. You can configure that which phone numbers must the device ringin gin case of input line changes. IVSMS parameter – in case of unsuccessful calling/ringing the SMS text message sending can be allowed.
  • Page 50: Standalone Alarm System Mode Settings

    In case of necessary you can save the configuration to your computer by the Save file button. Please, also check the Chapter 5.6 5.4 Standalone Alarm System mode settings Easy 2 In this operation mode the is operating as a standalone alarm system, when it is transmitting to a remite IP address or to the dispatching software - through GPRS.
  • Page 51 LFFREQ is the life signal sending frequency on GPRS channel, which is setup to 300 seconds by general. Check that it is fine or not. The LFUNIT value is the amount for the LFFREQ in seconds or minutes. disabling LFPRES value you can send hidden life signals (P603) to the dispatcher enabling center/IP-receiver (if it is supported).
  • Page 52 SWPROTO communication format to M2M which means the modified, special Contact ID protocol. This can be used only with the Enigma II, Enigma IP2 receiver devices, Alarmsys and SIMS dispatching software). If you’ve changed one of the listed parameter values, then the program will highlight the changed value lines by bold.
  • Page 53 Device Type view at the . Then the program will load the related parameters. Easy 2 All detected and received signals and events of the input lines are stored in a puffer with their timestamps, where 32 events can be stored temporary by the system. These will be transmitted/forwarded by the device through the defined network channel (GSM or GPRS connection) to the configured IP address.
  • Page 54 If you’ve changed one of the listed parameter values, then the program will highlight the changed value lines by bold. For sending the listed parameter values for the device Selected (regarding the coloumn) – check the proper selection – push the Write config button at the bottom of the screen.
  • Page 55 At this time, the ascending and descending edges are filtered through a time frame (the inputs must be hold for a minimal interval in the current status, to perform the further status change while the change is acknowledged). For the standalone alarm system modem there are some safety settings as the IxARM parameter, which is capable of granting that the current input line can transmit signal only in Armed...
  • Page 56 IxON parameter is used for SMS messaging for the input status, when the signal level is ascending from lowhigh, while the IxOFF is for the descending value from highlow (recovery). SMSFWD – forwarding only messages in SMS text messages to the phone number #1 (the mobile provider SMS notifications and SMS commands will be not forwarded).
  • Page 57 Siren and output settings configuring the siren/bark and output operation of the Output Settings parameter Device Type group at the . Then the program will load the related parameters. Here you can define values for the output line nr. #1 only. The IO-expansion settings for the further 3 outputs (nr.
  • Page 58 In mono-stable mode the output will be in standby (the relay contacts are opened) until a trigger event will be occured. In case of a trigger the output relay will close (shortened), then after a pre-defined delay interval automatically recovers to stand-by position. During the delay interval when a trigger comes then the timing will be restarted (e.g.
  • Page 59 The listed input parameters starting by the character „I” are value for the input numbers from #3 to #8 - according the requirements. The listed output parameters starting by the character „O” are value for the output numbers from #2 to #4. The ’x’...
  • Page 60: Monitoring Input Lines And Gate Opening Settings

    Please, also check the Chapter 5.6 5.5 Monitoring input lines and gate opening settings Easy 2 In this operation mode the is operating very similar to the mode which have been described at the Chapter 5.4, but the signaling is not performed to the dispatcher centre. In this mode, the GPRS network is used for remote control of the output lines, and the GSM network is utilized for messaging, for calling.
  • Page 61 On the input lines of the device it is capable of generating Contact ID messages and transmitting them by the ascending edge (L→H) and descending (H→L) edge. (The number of the current input is signed here by’x’). The length of the time frame can be configured by the IDELAY in 20 msec steps, which is enabled...
  • Page 62 monitoring external devices through the input line. The feature generates alarm at every signals change. If you’ve changed one of the listed parameter values, then the program will highlight the changed value lines by bold. For sending the listed parameter values for the device Selected (regarding the coloumn) –...
  • Page 63 TELx – SMS notification can be setup for max. 4 phone numbers It can be defined by the parameter that in case of input status changes for which phone numbers must the device sending SMS text message notification. Choose one from the possible notification sequence combinations.
  • Page 64 For monitoring a sabotage switch or further sensors, the CID event code must be defined at IxEVENT parameter, with the partititon number (IxPART), zone (IxZONE). (The ’x’ means the number of the input line in the name of the parameter). Here you can define values only for the input line nr.
  • Page 65 gate opening, controling the output line – to remotely switch by SMS text message or a voice call/ringing –change the OUTMODE value to Gate. The output has two peration mode: a mono-stable and a bi-stable. The mode can be configured by the OUTHDELx parameter.
  • Page 66: Further Safety Settings

    The listed input parameters starting by the character „I” are value for the input numbers from #3 to #8 - according the requirements. The listed output parameters starting by the character „O” are value for the output numbers from #2 to #4. The ’x’...
  • Page 67 Easy 2 By the CIDUNCACK parameter you can that the will send immediate and automatic acknowledge to the alarm center – independently that the signalling to the centre was sent successfully or not. This could be important for some alar, centers where the handshake for alarm signalling is not imporant or not available.
  • Page 68: Firmware Update/Refresh From Ftp Server

    international useg – between foreign mobile operators through the roaming). Always be informed about the international (roaming) usage conditions of the SIM card and GPRS data transmitting service – ask you mobile operator! If you’ve changed one of the listed parameter values, then the program will highlight the changed value lines by bold.
  • Page 69 enable You can define and the firmware refresh progress status SMS notification (in case of installation from an ftp server) by the FTPSMS parameter. You can setup the success text message for case of successful installation (by FTPSUCC parameter) and for case of failure (FTPFAIL parameter).
  • Page 70: Further Information About Operation Of The Easy 2

    Chapter 6. Further information about the Easy2 operation Easy 2 In this chapter you will find the main important information about the operation. 6.1 Primary and secondary communication channel Easy 2 is capable of signalling the incoming events to two communication channels to the remote dispatcher centre, via GPRS and by a GSM call.
  • Page 71: Signalling By Gsm Call

    The calls are limitid, as it can ring the same number only once in every 5 minutes. In case of voice call notification (ringing), the system sends an SMS text message Easy 2 call failed notification: " ".
  • Page 72: Voice Call Notification (Ringing)

    Visible and invisible life signal The visible life signal means that, when the device will send information to the dispatcher software only from the life signal outages. When the life signal is visible, then all sent life signals by the device will be visible in the dispatcher software. 6.6 Voice call notification (ringing) trigger For an input...
  • Page 73 The authentication will be performed by checking the caller’s number. The communicator rejects the call without any delay within the success of the authentication. enabled In case of successful authentication when the GATESMS parameter was , the caller (who remotely controls the gate) will receive an SMS notification about the status of the input (in mono-stable mode the delay value will be also reported).
  • Page 74: Configuration By Sms Messages

    Chapter 7. Configuration by SMS messages In this chapter you will found the executable commands and their descriptions which are possible to send through SMS text messages. By parametring the device by SMS commands the following rules must be considered: ...
  • Page 75: Query Commands

    You will receive a response SMS text notification with the queried values for answering the sent SMS command message. Command Response content Easy 2 INFDEV It will response a SMS report with the current statuses of the account nr. (customer ID), signal strength, software version,...
  • Page 76 Device restart, restrore of factory defaults, password Command Description RESET Restarts the device (manual restart which is needed to use after every parametring SMS command) ERASECONF Deletion of every the stored parameters and settings from the device memory (whole configuration delete) PWNEW Password change, adding the new password for connection authentication...
  • Page 77: Examples For Sms Command Parameters

    Standalone Alarm System specific commands – Arming/Disarming Command Description Easy 2 Arming the alarm status of the (activates the arming) Easy 2 DISARM Disarming the alarm status of the Gate opening, remote output control specific commands Command Description GATE For affection of the command the added new phone number...
  • Page 78 When the required parameters are not able to fit in one SMS command message, you can start a new, by using the PW= password authentication at first, then you can continue by the next parameter or command. You always have to use password authentication, in every parametring message the RESET command as the last!
  • Page 79 PW=ABCD,IOGPRS=1,I1EVENT=110,I1PART=01,I1ZONE=001,IDELAY=25,I1LHEN=1,I1INV= 0,I1ARM=0,TEL1=0036201234567,I1S=1,I1V=1,IVSMS=1,I1ON=FAIL,I1OFF=GOOD,SMSFW D=1,RESET PW=ABCD,ISABEVENT=331,ISABON=SABOTAGE,OUTMODE=0,SIRENOUT=1,SIRENDEL=30,RESE Standalone alarm system operation mode: There are sensors/sabotage switch connected to the input lines (2pcs of devices, by IO-expansion max. 8pcs) for monitoring, the siren is connected to the output line, and the signals are transmitted through GPRS network to the remote server IP address.
  • Page 80: Cid Code Table

    Chapter 8. CID code table Easy 2 We’ve collected the special Contact ID codes here into the following tables. Event CID code Alarm by an event - recovery 1407 Alarm by an event 3407 Alarm failure by an event 3454...
  • Page 81 Zone:  SMS – 0x10  TCP – 0x20  Serial – 0x30 (3) Login to Programming mode (for dispatcher centre) Parameter Description Easyterm In the in case of password authentication after login, the Easyterm following event generates, when the sends the LOGIN command to the device.
  • Page 82: Troubleshooting

    Please, ensure about the APN name or IP address and check the configuration of the device. Reconfigure the settings and wait while the device will be started by the new settings and operating properly. 4. Failed operation Easy 2 EasyTerm Check the firmware verion (by the SWVER value at the statuses).
  • Page 83: Signing The Status And Signal Strength Problems

    When the device was restarted or you’ve removed the powe supply, close the application. When you will adding the power adapter for the device or you’ve restarted it, and the operation of Easy 2 Connection window was prepared, then close the connection in the (1), by the Close button and remove the serial connection from the computer side.
  • Page 84 Inactive SIM card or SIM failure: Check that the SIM card was inserted properly. Contact with your mobile operator that the SIM is active and available. Mobil network service failure: If you are sure about the mobile network outage or GSM state providing trouble, and the is not...
  • Page 85 No SIM card presented or wrong SIM: SIM ICC When there is no available identifier. Turn off the device, and check the proper SIM card insertion, and start the device. Reconnect and check the settings.
  • Page 86: Support Availability

    Chapter 10. Support availability Should you have any questions regarding the usage of the device, you can contact us in the following ways: Email: support@m2mserver.com Telephone: +36 20 333 1111 10.1 Support help For identifying the device, please, use the sticker on the PCB, which contains important information to the support staff.
  • Page 87: Product Support

    10.2 Product support Click the following link to download the available product documentations and software: http://m2mserver.com/en/products/m2m-easy-2-security-communicator The documents and softwares related to the product are available at our website: http://m2mserver.com/en/downloads Online product support can be used at here: http://m2mserver.com/en/product-support...
  • Page 88: Legal Notice

    Chapter 11. Legal notice ©2017. WM Systems LLC. The content of this documentation (all information, pictures, tests, descriptions, guides, logos) is under copyright protection. Copying, using, distributing and publishing it is only permitted with the consent of WM Systems LLC., with clear indication of the source. The pictures in the user guide are only for illustration purposes.

Table of Contents