Connecting the communicator to the alarm panel

(+)
(-)
Green: RING
Yellow: TIP
White: IN1
Orange: OUT1
 WARNING: The wiring should be done only when the panel and the
communicator are disconnected from the powerline!
 Connect the RING and TIP of the alarm panel to the RING and TIP of the unit
 WARNING: Primary use only – NOT to be used with landline!
Having a phone line connected will damage the unit!
 Connect the antenna and place it outside of the alarm panel's box
 Connect + and – of the communicator to 12V-15V DC power supply

LED Indicator

 Slow flashing – trying to establish connection
 Constantly On – connection established at good signal level
 Constantly On, blinking every 5 sec – connection established at low signal level
 Fast flashing – transferring data

Configuring the alarm panel

Refer to the panel's installer manual to configure the following options:
 Enable the PSTN dialer of the panel
 Select DTMF mode (Tone dialing)
 Select Contact ID Full communication format
 Enter a telephone number for dialing (you can use any number, e.g. 9999999)
 Enter a 4-digit account number in the panel.
Configuration guides for popular panels are available at

Troubleshooting the DTMF communication

If you have issues receiving the events, try the following additional settings of the panel:
 Disable "Telephone line monitoring"
 Disable "Wait for dial tone" option
 Use "A" instead of "0" in the account number
 If there is more than one partition, enter an account number for each partition
 For certain panels, you might need also to specify an account number for the main
partition 0 (sometimes referred as system number)
Cellular Communicator with Dial Capture interface
12VDC Power Supply
Ground
(for the optional remote Arming/Disarming feature)
(for the optional remote Arming/Disarming feature)
www.MiNi01-4G.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MiNi01-4G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for M2M MiNi01-4G

  • Page 1 MiNi01-4G Cellular Communicator with Dial Capture interface Quick Installation Manual Connecting the communicator to the alarm panel 12VDC Power Supply Ground Green: RING Yellow: TIP White: IN1 (for the optional remote Arming/Disarming feature) Orange: OUT1 (for the optional remote Arming/Disarming feature) ...
  • Page 2  Wire that PGM to the IN1 (white wire) of the communicator Guidelines for configuring the keyswitch and the output for popular panels are available www.MiNi01-4G.com Initial pairing procedure:  Enable Open/Close reporting (at least during the initial pairing procedure) ...

Table of Contents