Table 8–1 Bypass Module Fault Code List (cont.)
Code
Status
indication
Message
(Note 2)
UF305
CTRL.CIRCUIT ERR.
UF306
CTRL.CIRCUIT ERR.
UF320
CTRL.CIRCUIT ERR.
UF321
CTRL.CIRCUIT ERR.
UF322
CTRL.CIRCUIT ERR.
UF323
CTRL.CIRCUIT ERR.
UF324
CTRL.CIRCUIT ERR.
UF325
CTRL.CIRCUIT ERR.
UF326
CTRL.CIRCUIT ERR.
UF327
CTRL.CIRCUIT ERR.
MODULE MINOR
UF340
FAULT
UF341
#1 MAJOR FAULT
UF342
#2 MAJOR FAULT
UF343
#3 MAJOR FAULT
UF344
#4 MAJOR FAULT
UF345
#5 MAJOR FAULT
UF346
#6 MAJOR FAULT
MODULE MAJOR
UF349
FAULT
UF371
CTRL.CIRCUIT ERR.
UF372
CTRL.CIRCUIT ERR.
UF374
CTRL.CIRCUIT ERR.
UF375
CTRL.CIRCUIT ERR.
58
Meaning
Detection of an abnormal clock
speed in the CPU or FPGA.
Control power supply voltage is
below the specified level.
Cable disconnection in the
parallel interface board during
load supply (SMS).
Cable disconnection in the
parallel interface board during
load supply (Individual Bypass
System).
Major communication error during
parallel operation (ΔI).
Major communication error during
parallel operation (CAN).
Major communication error in
both of the CAN signals during
certain period.
Major communication error by
fall-out of both of dual
connectors.
Communication integrity error or
No communication (SMS).
Communication integrity error or
No communication (Individual
Bypass).
A power converter module has
detected major fault condition.
Power converter module #1 has
detected major fault condition.
Power converter module #2 has
detected major fault condition.
Power converter module #3 has
detected major fault condition.
Power converter module #4 has
detected major fault condition.
Power converter module #5 has
detected major fault condition.
Power converter module #6 has
detected major fault condition.
All Power converter modules
have detected major fault
condition.
Major communication error in
either of the CAN signals during
certain period.
Unable to synchronize the
inverter output and the bypass
voltage.
Cable disconnection in the
parallel interface board.
Unable to achieve
synchronization for parallel
operation.
G9000 1000-2000kVA Installation and Operation Manual 91469-007
Audible
Guidance
Alarm
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Continuous
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
CALL
Intermittent
SERVICE
sound
ENGINEER
External
relay
contact
(Note 1)
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor