Download Print this page

Schlage CM5100-KPI Installation Manual page 3

Computer managed cylindrical lock cm5100 series

Advertisement

2. INSTALL CYLINDER (IF NOT ALREADY DONE), GASKET AND STANDOFFS:
A. Install cam onto cylinder (if not already done.) Cam must be a straight, 11/16" design. See below for recommended
cams.
B. Insert mortise cylinder into outside escutcheon from front (keypad/reader) side with keyway down.
C. Slide lock washer onto cylinder (tab on top facing out, as shown below.)
D. Using nut tool (provided) tighten nut onto cylinder.
E. Line up nearest notch on nut with tab on lock washer and bend tab using nut tool so nut is secure.
F. Install exterior gasket (if used).
G. Install standoffs.
TEST KEY OPERATION NOW: Turning key clockwise until it stops (about 1/2 turn) should allow the lever to turn retractor.
RECOMMENDED CAMS:
SCHLAGE EVEREST: P/N B502-948
SCHLAGE CLASSIC: P/N B502-191
CYLINDER
RETRACTOR ASSEMBLY
Form 51005 Rev. D
CM5100 COMPUTER MANAGED CYLINDRICAL LOCK
:
NOTE
BLOCKING RING REQUIRED FOR CYLINDER
LENGTH GREATER THAN
THICKNESS = CYLINDER LENGTH - 1 1/8"
3
INSTALLATION MANUAL
1-1/8".
TAB
LOCK WASHER
NUT
NUT TOOL
STANDOFFS
EXTERIOR GASKET
12-02-2002

Advertisement

loading

This manual is also suitable for:

Cm5100-mgkCm5100-iboCm5100-mgiCm5100-pxkCm5100-ppkCm5100-pck ... Show all