7. INSTALL INSIDE SPINDLE, BATTERIES, AND INSIDE ESCUTCHEON:
NOTE: The lock is shipped with four AA alkaline batteries. Always use new, high quality alkaline batteries.
A. Plug wiring harness into PC board.
B. Tuck wiring harness under retaining clip as shown in detail.
C. Install four AA batteries as shown, note polarity indication on battery holders.
D. Insert inside spindle with flat side showing.
E. Install inside escutcheon with four screws, making sure that the inside spindle engages the lever cam.
F. Test operation of inside lever to make sure that latch retracts fully.
INSIDE SPINDLE
(
FLAT SIDE FACES TOWARD LEVER
INSIDE ESCUTCHEON
Form 51005 Rev. D
CM5100 COMPUTER MANAGED CYLINDRICAL LOCK
)
7
INSTALLATION MANUAL
WIRE HARNESS
RETAINING CLIP
INSIDE IBUTTON
READER
WIRE HARNESS
(CM5198 ONLY)
(
PHILLIPS SCREWS