Active front end (NXA)
Allowed cooling
agents
Volume
Temperature of
cooling agent
Liquid cooling
Cooling agent flow
rates
System max. working
pressure
System max. peak
pressure
Pressure loss (at nom.
flow)
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
Table 61. Technical data
Drinking water (see specification on page 49)
Water-glycol mixture
See derating specifications, Chapter 5.3.
See Table 19.
0...35 °C input (I
see Chapter 5.3.
Max. temperature rise during circulation max. 5 °C
No condensation allowed. See Chapter 5.2.1.
See Table 15.
6 bar
30 bar
Varies according to size. See Table 17.
); 35...55 ºC: derating required,