Section 4
Installation, Connections, and Wiring

Installing ID Tags

V680-D1KP52MT
Tag Installation
Mount Tags as shown in the diagram on the right. The epoxy
adhesives listed in the following table are recommended for the
given temperature ranges.
Ambient
operating
temperature
−40 to 70°C
−40 to
150°C
When embedding the V680-D1KP52MT into a metal surface, use the V680-HS51/-HS52 Antenna.
Transmission will not be possible if the V680-HS63 Antenna is used.
V680-D1KP66T
Mounting on Non-metallic Material
Mount the ID Tag using M3 pan-head screws from the
marked side.
Tightening torque: 0.3 to 0.5 N·m
Mounting on Metal
The communications distance will decrease if there is
metal at the back of the V680-D1KP66T ID Tag.
If the ID Tag is mounted to metal, use the separately
sold Special Attachment (V600-A86) or a non-metallic
spacer (e.g., plastic or resin).
Refer to Effect of Metal behind Tags (Reference) in Section 6 Appendices for information on the effect of metal behind
the V680-D1KP66T.
RFID System
44
User's Manual
Product name
Two-part Epoxy-compound Resin:
TB2001 (main agent)/TB2105C (curing agent)
One-part Moisture-curing Elastic Adhesive
TB1530
One-part Epoxy Resin: TB2285
Two-part Epoxy Resin: TB2087
p.107
8.1
Manufacturer
Three Bond
Co., Ltd.
Three Bond
Marked side
Co., Ltd.
Three Bond
Co., Ltd.
Marked side
Three Bond
Co., Ltd.
Mounting Hole Dimensions
M3 pan-head screw
25
Marked side
M3 pan-head screw
Mounting Hole Dimensions
Marked
side
25
±0.2
Attachment (V600-A86)
R0.2 max.
+0.1
dia.
0
+0.1
5
0
Two, M3
±0.2
25
±0.2
Two, M3
25
±0.2