Grizzly G0808 Owner's Manual page 30

Variable-speed gearhead drill press w/cross-slide table
Table of Contents

Advertisement

Limit Stops
Use X- and Z-axis limit stops (see Figures 37–38)
in conjunction with each power feed to set the
total amount of travel. The limit stops come into
contact with the limit switch and stop power feed
motion.
If not being used, position stops as far away from
limit switches as possible, so as not to interfere
with table movement.
Tools Needed
Hex Wrenches 5, 12mm ..............................1 Ea.
To adjust the position of the X-axis limit stops (see
Figure 37), loosen the cap screws that secure the
stops, move the stops to the desired positions,
then tighten securely.
X-Axis
Limit Stop
(1 of 2)
Figure 37. X-axis limit switch and stops.
To adjust the position of the Z-axis limit stops,
loosen the stop bracket bolts, raise or lower the
stops to the desired positions, then retighten bolts
(see Figure 38).
Z-Axis
Limit Switch
Figure 38. Location of Z-axis limit switch and
upper stop with stop bracket bolt.
-28-
Qty
X-Axis
Limit Switch
Stop Bracket
Bolt (1 of 2)
Z-Axis
Limit Stop
(1 of 2)
Operating Power Feed
The X- and Z-axis power feed units operate in a
similar way. Therefore, use the following instruc-
tions to operate both units. For additional compo-
nent details, refer to Power Feed Identification
on Page 6.
To operate X- or Z-axis power feed:
1.
Loosen table lock(s).
2.
Turn speed dial (see Figure 39) all the way
counterclockwise to slowest setting.
3.
Move direction lever to neutral (middle)
position, then move ON/OFF switch (see
Figure 39) to ON position.
4.
With your hand poised over ON/OFF switch
in case you need to suddenly turn unit OFF,
move direction lever (see Figure 39) to select
desired direction of table travel.
5.
Use speed dial (see Figure 39) to slowly
bring speed of movement up to desired rate.
To cause table to instantly move at full speed
when already in motion, press rapid traverse
button (see Figure 39). The table will resume
previous speed when button is released.
Rapid Traverse
Button
Speed
Dial
Reset
Button
Figure 39. Power feed controls (Z-axis shown).
6.
When you are finished using power feed, turn
unit OFF, rotate speed dial all the way coun-
terclockwise, and move direction lever to
neutral (middle) position to avoid unexpected
table movement later.
Model G0808 (Mfd. Since 11/15)
Direction
Lever
ON/OFF
Switch

Advertisement

Table of Contents
loading

Table of Contents