K 2201
Wet-vacuuming
Never use this cleaner to vacuum explosive
liquids, acids or solvents.
• The paper filter bag must be removed before
using the cleaner for wet-vacuuming.
• The filter cartridge can remain in the unit. It
must however be allowed to dry out before the
cleaner is used for dry-vacuuming again.
• If the container is full, the float closes the inlet,
the suction power is reduced, and the suction
motor runs at a higher speed. When this
happens, switch off and unplug the cleaner
from the mains electricity.
• Hold the hose up high to allow any liquid to
flow into the container.
• Cleaning can be continued as soon as the
container has been emptied.
Emptying the container
• Release the container clips, lift off the
vacuuming assembly, and lay it on its side.
• Within a short period of time wet dirt will start
to decay, therefore empty the container after
each use, and rinse it out with clean water.

Troubleshooting

Problem
Motor (suction turbine) does not
work
Suction power drops off gradually Blocked filter cartridge, nozzle,
Suction power drops off suddenly Full paper filter bag or container
Dust is expelled during
vacuuming
Replacing and cleaning the filter
cartridge
• Release the container clips, lift off the
vacuuming assembly, and lay it on its side.
• Undo the bayonet catch holding the filter
cartridge in place (Illustration D).
• Pull filter off, and clean with a soft brush.
It can also be rinsed under running water
(Illustration E). Allow the filter to dry out
before the cleaner is used for dry-vacuuming
again.
• Place the vacuum assembly onto the
container, and secure with the clips.

Technical specifications

..................................................... 1.085-281
..................................................... 1.085-601
Voltage
Mains fuse (slow)
Container volume, net
Water intake capacity
Blower data
Air flow rate
Vacuum
Weight
Class of protection
Mains cable
Sound pressure level
Specifications subject to change without prior
notice.
Cause
No power supply
suction hose or tube
Defective or improperly fitted filter
cartridge
240
1~50/60
12
18
8
P
1200
MAX
P
1000
NOM
55
175
6
II
Type
H05VV-F2x1
74
Remedy
Check building fuse, mains cable
and socket.
Check, clean
Switch off unit, and empty
container. Replace filter bag.
Check filter fitting; replace filter
cartridge if required