ARM/DISARM pARtIAlS AnD GoRup
When the system is disarmed, digit personal code (default 111111).
The screen that appear will be the program and/or group that is linked
to the code, aFter 3 seC. start tHe COuntDOWn OF arminG.
Before starting time exit (3 sec.) it is possible change the program
and/or group by using the number keys and G keys. Figure 2 shows
the activation of partial 1, the line above shows the name and the
line below shows which partial was selected.
Fig. 3 shows the activation of Group (1 and 2). By using G key.
after selection in 3 sec. will start again time exit.
note: partial selection is step-by-step so pressing the number of
the partial more than once turns it off and back on.
ARM/DISARM gRoupS by quIck ARM
Each group can be given a name and be associated with the desired partials.
Once programmed, activation is done in the same manner as the partials (see below ... ARM and DISARM)
with G keys it is possible set the quick ARM (arming without code, 1 touch). For set quick code, go in other parameters, menu QUICK
ARM and enable (switch to 1). For modify the Group (G 1-2-3-4) that be start without code, set the user 32 or 64 of panel, this user
is used for set the quick code. after settings when one of G is pressed will start the arming Group (G).
For change the group before starting press anothe G keys in 3 seconds before starting time exit.
In the figure, the group called "PERIMETER" is made up of 3 partials (2-3-4)
note: When is active the option en 50131 is not possible arm the panel when there are the following troubles:
no main power, battery low, tamper, line tamper, peripheral tamper, no gsm, no lan, interconnection between
devices, wireless fault wake up.
Bypass zone
There are 2 different way of bypass: eXClusiOn and inHiBitiOn.
EXCLUSION (P) = Permanent mode, the zone will remain bypassed always. For unbypass you need go in specify menu
INHIBITION (t) = Temporary mode, the zone will remain bypassed only for actual arm, after disarming the zone will return ready.
NO BYPASS ( ) = No bypass, the zone is ready
NO BYPASS ( )=No bypass, the zone not ready
Bypass with not ready zones: during in the arming procedure the system show the message zones not ready, and invite to
select the buttons for check,bypass, include (1 = include, 2 = inhibition, 3 = check) when is pressed 3, the system will show the
menu of bypass (fig)
BYPASS ZONES
V-Select
press ENTER for go in menu zone bypass, press X key for choose between P t
Bypass with system ready (all zone closed): during in the arming procedure, immediately after selected partitions, press X
button to go in the bypass menu, the procedure is the same.
When the system is armed with bypassed zones, the type is armed will be FOrCeD in event log it is possible to see witch zone is
bypassed and in witch way.
www.amcelettronica.com
G1
G2
G3
PERIMETER
fig2
- 2 3 4 - - - -
82
fig1
fig2
fig3
G4
[01] Zone 01
P T
Total
1234
program 1
1 - - - - - - -
perimetric
1 2 - - - - - -
KX series v.1.70