programming panel with Software

It is possible program the panel via software, DBexplorer.
There 2 mode for programming: local and remote via cloud system.

local programming:

- adapter connector COM/USB
- driver for COM/USB
- a cable USB to mini USB standard
- DBexplorer Software
Set the telemanagement code (default is 7777777) via keypad go to user code, in installer editor(defalut code 000000) and set
telemang. code, the same code must be set in the soft, in the tab of user infomartions.
Enable the panel for soft programming, via keypad go to user menu (default 111111) set the menu enable telemang. and set 1.
Open the soft db explorer and set the parameter of comunication serial port.
Now it is possible change, send and get all setting from or to the panel.
remote programming, via cloud service:
- Panel must be connected to the cloud with IP board and/or GPRS module
Set the telemanagement code (default is 7777777) via keypad go to user code, in installer editor(defalut code 000000) and set
telemang. code, the same code must be set in the soft, in the tab of user infomartions.
Enable the panel for remote soft programming, via keypad go to user menu (default 111111) set the menu enable telemang.
and set 2 remote cloud programming.
imPOrtant: when is enabled the remote programming, set 2, the aPP will be inactive for all time that this op-
tion is on 2 mode.
Open the soft db explorer and set the parameter of comunication remote programming, and Put the uiD CODe in the space tab.
note: the uiD CODe must be copied from installer editor in the netWOrK menu --> ClOuD aCCOunt.
Now it is possible change, send and get all setting from or to the panel.