Output Expansions Kxout; Expr/S Radio Expansion - AMC KX Series Installer Manual

Alarm control unit
Table of Contents

Advertisement

OUTPUT exPansiOns "KxOUT"
The control unit has 1/2 outputs, which can be expanded by using the optional Expus module.
The module must be connected to the BUS-485 line with the respective terminals A, B, +12V and -.
Before providing power to the system, in order to differentiate the peripherals, you must address them using their microswitches
(DIP-SWITCHES), referring to the following figure.
CANC
1
5
For the use of O.C. outputs, refer to the manual, paragraph CONNECTIONS - OUTPUTS.
9

expr/s radio expansion

The 32 device radio receiver is connected to the control unit through the bus 485 line. A maximum of 2 can be connected to the
control unit.
There are 2 pairs of dipswitches with 2 and 4 selectors:
C
- HD ADR = the address
- Tied to the radio receiver section
Follow the drawing below for coding the bus address.
note: dipswitches with 4 selectors only use dipswitch no. 3 which enables the cover anti-opening protection.
(leaVe tHe OtHer DiPsWitCHes OFF)
www.amcelettronica.com
Configurazione DIP-SWITCH
DIP-Switch Configuration
2
Please note: in COnFiGuratiOn 1 all DiPsWitCHes are OFF
6
0
not certified EN 50131
D
Please note: in COnFiGuratiOn 1 all DiPsWitCHes are OFF
3
7
A
E
DIP-Switch Configuration
36
4
8
B
F
KX series v.1.70