AMC KX Series Installer Manual

Alarm control unit
Table of Contents

Advertisement

www.amcelettronica.com
kX SerieS
alarm control unit
installer manual
EN 50131-1
EN 50131-3
EN 50131-6
EN 50136-1
EN 50136-2
CLASS II
1
KX series v.1.70

Advertisement

Table of Contents
loading

Summary of Contents for AMC KX Series

  • Page 1 SerieS alarm control unit installer manual EN 50131-1 EN 50131-3 EN 50131-6 EN 50136-1 EN 50136-2 CLASS II www.amcelettronica.com KX series v.1.70...
  • Page 2 / or theft or other types of issues caused by an incorrect installation and / or configuration of the system.
  • Page 3 - programming Software installDBexplorer - fisher for fix on the wall the palstic box The material not included in the box can be purchased except: the programming software and Installation manual can be downloaded from our site: www.amcelettronica.com www.amcelettronica.com KX series v.1.70...
  • Page 4 The delete of events can be made only by the manufacturer. deviceS for control of the SyStem There are 2 type of device for control of panel: Type A: Klcd and Klight Type B: Klight plus see the explanation in this manual www.amcelettronica.com KX series v.1.70...
  • Page 5 8 for SMS + 8 for protocols carriers PSTN on board, GSM/GPRS module, IP module other inputs TAMPER line / mechanical antiopening tamper PC software remote manage- HTML page ment apps (Apple - Android) IP - GPRS timers 8 per day week www.amcelettronica.com KX series v.1.70...
  • Page 6 4 numbers with another 4 for backup carriers PSTN on board, GSM/GPRS module, IP module other inputs TAMPER line / mechanical antiopening tamper PC software remote management HTML page IP - GPRS apps (Apple - Android) timers 4 per day week www.amcelettronica.com KX series v.1.70...
  • Page 7 -10 °C - + 40 °C Maximum Humidity 75% (non-condensing) Klight - Klight plus - KXin - KXOut - Xgprs - iP1 enVirOnmental COnDitiOns Environmental Class class II Temperature -10 °C - + 40 °C Maximum Humidity 75% (non-condensing) www.amcelettronica.com KX series v.1.70...
  • Page 8 -10 °C - + 40 °C Maximum Humidity 75% (non-condensing) Klight - Klight plus - KXin - KXOut - Xgprs - iP1 enVirOnmental COnDitiOns Environmental Class class II Temperature -10 °C - + 40 °C Maximum Humidity 75% (non-condensing) www.amcelettronica.com KX series v.1.70...
  • Page 9 - Connect the terminal tamper to the socket on the panel board - Remove the plastic tower from the bottom of the box Fig.4 - Connect the tower to the socket on the cover Fig.5 In this way the system is protected from open and remove www.amcelettronica.com KX series v.1.70...
  • Page 10 - Connect phase, neutral and earth to the fuse housing like in figure - make sure that the earth connection is like the fig in next page imPOrtant: Pay max attention during the cabling imPOrtant: to avoid electric shock, wiring system without power www.amcelettronica.com KX series v.1.70...
  • Page 11 Wiring the earth like figure below: An example of wiring of the system: www.amcelettronica.com KX series v.1.70...
  • Page 12 The system check the status of battery every 10sec. , when the level of battery go down 10.4V the system will notify the discharge battery with a led alert in keypad. When the voltage exceeds 11.4V the system will notify the correct charge of battery. www.amcelettronica.com KX series v.1.70...
  • Page 13 Drill, taking care not to damage any piping in the back of the wall. Insert for each hole, 1 fisher with dimater of 6mm Slide the cables through provided holes Fix the box on the wall with the right screw for fisher metal box for battery 7ah www.amcelettronica.com KX series v.1.70...
  • Page 14 17ah www.amcelettronica.com KX series v.1.70...
  • Page 15 In metal box the tamper is used for opnening protection. In figure is shown how to work: - fix the tamper switch (1) to the metal blade (2) - Connect the terminal tamper to the socket on the panel board (3) tamper closed www.amcelettronica.com KX series v.1.70...
  • Page 16 - The erath is bring to the panel by metal box, the connection is made from screw of fuse housing and metallic turrets on panel screw for connnect the earth box metal turret for bring earth to the board battery place For bring the earth on closing lid of the box, use the faston terminal (see fig.) www.amcelettronica.com KX series v.1.70...
  • Page 17 When the voltage exceeds 11.4V the system will notify the correct charge of battery. metal box for 17ah battery view Battery housing 17ah lead-acid batteries with ul94-HB flammability or higher. important: attach biadhesives under the battery compartment, for fix battery and and avoid vibrations. www.amcelettronica.com KX series v.1.70...
  • Page 18 7ah battery view lead-acid batteries with ul94-HB flammability or higher. Battery housing important: attach biadhesives under the battery compartment, for fix battery and and avoid vibrations. www.amcelettronica.com KX series v.1.70...
  • Page 19 - FLASHING YELLOW : PSTN calling status Jp1 and Jp2 Jumper on board these jumpers must remain open Are used for updating the firmware and total reset of the parameters. The guide for these is in the tool for upgrade FW panel. www.amcelettronica.com KX series v.1.70...
  • Page 20 - FLASHING YELLOW : PSTN calling status Jp1 and Jp2 Jumper on board these jumpers must remain open Are used for updating the firmware and total reset of the parameters. The guide for these is in the tool for upgrade FW panel. www.amcelettronica.com KX series v.1.70...
  • Page 21 MIC red led = only blink during on record audio Jp1 and Jp2 Jumper on board these jumpers must remain open Are used for updating the firmware and total reset of the parameters. The guide for these is in the tool for upgrade FW panel. www.amcelettronica.com KX series v.1.70...
  • Page 22 For fix the Keypad on the wall, use fisher of 4mm. For removing protection fix 1 fisher in the specific hole (see fig.) K LCD is equipped with 4 terminal: + A B - (RS 485) = bus terminals for peripheral connection (see chapter fo bus connection) Power supply voltage: 13.8Vdc Rated current: 25mA Maximum current: 160mA www.amcelettronica.com KX series v.1.70...
  • Page 23 Knock out (where necessary) the points B, for cable entry. Fix the bottom of the box plastic, with 2 screws at points A Fix the board at points C nOte: The fix points A, also serve for the back tamper system www.amcelettronica.com KX series v.1.70...
  • Page 24 COM 1-2-3 =COM terminal reference kXout board deScription DIP-Switch Configuration IANTO Configurazione DIP-SWITCH CANC MORIA note: in COnFiGuratiOn 1 all DiPsWitCHes are OFF NTROLLO Jumper COm: right part: positive reference Jumper COm: left part: negative reference www.amcelettronica.com KX series v.1.70...
  • Page 25 IP1 is the module for connect the panel in to the web for AMC Cloud (smartphone app managing), and for sending monitoring station data via web. Is plugged directely on the main board of panel in SOCKET EXP:...
  • Page 26 10/100 BASE TX IEEE 802.1x Full Duplex PrOtOCOl: Base: TCP/IP Encrypt: TLS/SSL Data: AMC Protocol V1.0 for system serie C-X-K leD: GREEN ON = OK “comunication to system ok”. GREEN BLINKING = FAIL “no comunication to system” (Enable IP expansion on menu) YELLOW BLINKING = system running.
  • Page 27 XgprS module XGPRS is the module for connect the panel in to the web for AMC Cloud (smartphone app managing), and for sending monitoring station data with a GSM data SIM. Is plugged directely on the main board of panel in SOCKET EXP, or on the IP1 socket like a backup for IP1 board.
  • Page 28 (4’’) in use on Cloud data sending blink green 100ms GPRS multicolor Status 1sec. green blink data receiving blink orange 100ms in connection blink orange 1sec. Cloud comunication for connect red steady on Error initializzation www.amcelettronica.com KX series v.1.70...
  • Page 29 You can also use the outputs with the PULL UP resistors (value 1K) to vary the reference voltages, ex. to have positives and nega- tives that change based on a certain programmed event. Following are a few examples of O.C. output connections: www.amcelettronica.com KX series v.1.70...
  • Page 30 With split zone (only for K series) it is possible to have different zone, 2 or 3 separate zone directely on 1 terminal. For EOL resistor it is possible to select different value, with different combination. The following is the diagram for connecting the zone inputs: 1 eOl resistor, with selectable resistor values: not certified en 50131 www.amcelettronica.com KX series v.1.70...
  • Page 31 2 eOl resistors, 1 zone with cut and short circuit protection, follow selectable resistors values: certified en 50131 2 zones with cut wire protection, follow selectable resistors values: not certified en 50131 www.amcelettronica.com KX series v.1.70...
  • Page 32 2 zones with cut and short circuit protection, follow selectable resistors values: certified en 50131 triple eOl protection: alarm - tamPer - masKinG not certified en 50131 3 zones with cut wire protection: not certified en 50131 www.amcelettronica.com KX series v.1.70...
  • Page 33 It is possible use these zone in all place except on board (eg. on panel from 01 to 08 is not possible, it is possible from zone 09). For output configuration you can increase the total number of output from panel that is connected (k light plus). www.amcelettronica.com KX series v.1.70...
  • Page 34 The cable must be connected between the PHONE terminals side (see board figure) and the SPK terminal on the K-LCD VOICE keyboard. note: To enable anti-opening protection, open the jumper on the back of the board Configurazione DIP-SWITCH CANC DIP-Switch Configuration Please Note: in CONFIGURATION 1 ALL DIPSWITCHES ARE OFF www.amcelettronica.com KX series v.1.70...
  • Page 35 Before providing power to the system, in order to differentiate the peripherals, you must address them using their microswitches (DIP-SWITCHES), referring to the following figure. Configurazione DIP-SWITCH CANC DIP-Switch Configuration Please note: in COnFiGuratiOn 1 all DiPsWitCHes are OFF www.amcelettronica.com KX series v.1.70...
  • Page 36 Follow the drawing below for coding the bus address. note: dipswitches with 4 selectors only use dipswitch no. 3 which enables the cover anti-opening protection. (leaVe tHe OtHer DiPsWitCHes OFF) DIP-Switch Configuration Please note: in COnFiGuratiOn 1 all DiPsWitCHes are OFF www.amcelettronica.com KX series v.1.70...
  • Page 37 KX series v.1.70...
  • Page 38 - If the zone with ENTRY/EXIT function remain not ready at finish the exit time, the panel block the arm and show in keypad - Every time the panel stop arming procedure for trouble, in keypad display appear the cause that block, and start sound for 60’’ second. For stop sound alert set the user code. www.amcelettronica.com KX series v.1.70...
  • Page 39 In the figure above the terminal 1 is a input in 09 place, the terminal 2 is an output at place 05 After this configuration go in the input and/or output parameter and program like a normal zone or output www.amcelettronica.com KX series v.1.70...
  • Page 40 ENTER with orizz. arrow select option and with X select dot or square to enable option Confirm with ENTER A = answer confirmation by pressing # B = direct menu panel access (without code) C = reset call progress www.amcelettronica.com KX series v.1.70...
  • Page 41 = Pstn KO Notification of PSTN line fail event m16 = Pstn OK - Notification of PSTN line restore event m17 = fault connection www.amcelettronica.com KX series v.1.70...
  • Page 42 - Insert the numbers that correspond to the words using the number keys - Press CANCEL to delete the existing name - At the end, confirm with ENTER note: the following is a complete list of the words available. the numbers indicate the parameter to enter. www.amcelettronica.com KX series v.1.70...
  • Page 43 131 reduced 166 tamper 062 cellar 097 inserted 132 pool 167 shade 063 system 098 internal 133 door 168 keypad 064 center 099 irrigation 134 arcade 169 tavern 065 lock 100 laundry 135 doorway 170 camera www.amcelettronica.com KX series v.1.70...
  • Page 44 144='SECRETARIAT'; 30='LOCK'; 68='DAY'; 106='PROGRAM1'; MSG183='GLASSDOOR'; 145='SIX'; 31='BOX'; 69='GREAT'; 107='PROGRAM2'; MSG184='SHOWCASE'; 146='BASEMENT'; 32='BOILER'; 70='GROUP'; 108='PROGRAM3'; MSG185='VOLUMETRIC'; 147='DETECTOR'; 33='ROOM'; 71='FAILS'; 109='PROGRAM4'; MSG186='ZERO'; 148='SEVEN'; 34='SMALLROOM'; 72='FAILURE'; 110='PROGRAM5'; 149='LEFT'; 35='POUND'; 73='LIGHTING'; 111='PROGRAM6'; 150='SIREN'; 36='GATE'; 74='FIRE'; 112='PROGRAM7'; 151='RESCUE'; 37='CELLAR'; 75='INERTIAL'; 113='PROGRAM8'; www.amcelettronica.com KX series v.1.70...
  • Page 45 No EOL (N.C. or N.O.) • Switch Alarm (hight speed Pulse Counter) • Wireless • EOL SEQUENCE: • 1BAL 1K • 1BAL 2K2 • 1BAL 3K3 • 1BAL 3K9 • 1BAL 4K7 • 1BAL 6K8 • 1BAL 8K2 www.amcelettronica.com KX series v.1.70...
  • Page 46 • 4k7 Mask • 2 Zones • 4K7 Zone 1 • 8K2 Zone 9 • 2 Zones • 4K7 Zone 2 • 2K2 Zone 10 • 2 Zones • 3K9 Zone 1 • 6K8 Zone 9 www.amcelettronica.com KX series v.1.70...
  • Page 47 This parameter it is usable for all configuration type of inputs. [01] zone 01 With dot the polarity is N.C. with squarethe polarity is N.O. Enter in the parameter and press ENTER when the cursor flashing use CANCEL for change from dot to square. www.amcelettronica.com KX series v.1.70...
  • Page 48 - Use the LEFT and RIGHT arrows to select the desired input, then press ENTER again - Insert the letter that corresponds to the function - Press CANCEL to delete the existing name - At the end, confirm with ENTER [01] - Input 01 RRRAAAAAHHSTZY www.amcelettronica.com KX series v.1.70...
  • Page 49 - Use the up and down arrows to select the desired input, then press ENTER again - Enter the desired value when the cursor flashes - Press CANCEL to delete - At the end, confirm with ENTER www.amcelettronica.com KX series v.1.70...
  • Page 50 - Use the RIGHT and LEFT arrows to select the desired input, then press ENTER again - Use the number keys to define the setting - Press CANCEL again to delete - At the end, confirm with ENTER www.amcelettronica.com KX series v.1.70...
  • Page 51 - Use the RIGHT and LEFT arrows to select the desired input, then press ENTER again - Use the number keys to define the setting (only S) - Press CANCEL again to delete - At the end, confirm with ENTER www.amcelettronica.com KX series v.1.70...
  • Page 52 Outputs that can be activated by a phone ring with programmed ID. The activation is step-by-step (Ring = activation --> ring = deactivation) or, if a pulse sound time is set. At each ring activation, the operation will be confirmed by an answering ring www.amcelettronica.com KX series v.1.70...
  • Page 53 The figure shows only the first 4 outputs programmed. The following ones, are not assigned any function. As always, the menu is the horizontal type, therefore once inside, when the cursor flashes, use the horizontal arrows to select the outputs and use the keypad to set the function. www.amcelettronica.com KX series v.1.70...
  • Page 54 Ex. 2 O2 with NO 220ac function with a 1 hour delay - the 220Vac power returns within a half hour and the output does NOT interrupt the delay BUT CONTINUES the activation process. AFTER AN HOUR IT IS ACTIVATED. www.amcelettronica.com KX series v.1.70...
  • Page 55 Ex. an input can move 2 outputs, one with the system armed (garden lights) and one with the system disarmed (entry door courtesy light) 001 - input one In the figure you can see output no. 1 has the first 2 inputs associated. www.amcelettronica.com KX series v.1.70...
  • Page 56 In figure above, is explained the menu for add devices with ID code ------------------ In figure above, is explained the lcd display of self learning mode and manual set code. Every new learn, the number of free device programmable decrease. www.amcelettronica.com KX series v.1.70...
  • Page 57 Switch alarm contact, it is possible set the number of PulsesSwitch pulses. D01-CU800 Nr.01 - Led of indication it is possible enable or disable the alarm/transmission led on the device (0 = disabled 1 = enabled) Led device www.amcelettronica.com KX series v.1.70...
  • Page 58 - Range - Battery status - Supervision - Id number For set the parameters of sound duration, squawk, cycles etc. go in menu siren in other parameters. All sirens settings are the same for wired and wireless. www.amcelettronica.com KX series v.1.70...
  • Page 59 OFF) In this LCD mask PRESS ENTER TO MODIFY. It is possible modify these parameters for all buttons. D01-TR800 Nr01 In figure is shown that the Key TOT button is programmed like only ON and are linked the partitions: 1345678 1-345678 www.amcelettronica.com KX series v.1.70...
  • Page 60 It is possible check in the real time the radio disturbance percentage near the receivers. In the figure below you can see 2 different disturbance thresholds in 2 receivers. note: the radio disturbance notification is done by the control unit when the threshold exceeds 50% for more than 5 seconds. WIRELESS WIRELESS EXPR1 RSSI EXPR2 RSSI www.amcelettronica.com KX series v.1.70...
  • Page 61 - RIGHT and LEFT arrows to select the partial, then press ENTER - Enable it by pressing CANCEL when the cursor flashes Perimeter - Press CANCEL again to delete - At the end, confirm with ENTER www.amcelettronica.com KX series v.1.70...
  • Page 62 This parameter is used when is disable the line control, the system take the line and wait few second before start the composistion, the pause is used for allow the line to go in stable level. Normally when is active the control the system detect when can start the composition, when is disabled is important set a pause. www.amcelettronica.com KX series v.1.70...
  • Page 63 No220V arming block. 0 = unlocked 1 = locked ARMING LOCK Battery ARMING LOCK Tamper ARMING LOCK Line Tamper ARMING LOCK Periph. Tamper ARMING LOCK NoGsm ARMING LOCK interconnection ARMING LOCK Wirel. Inactiv ARMING LOCK NoPstn www.amcelettronica.com KX series v.1.70...
  • Page 64 00:00 The following screens indicate the association Timer 01 - Sun of timer 1 to the users, partials and outputs Fig. 3 PROGRAMS Timer 01 - Sun fig 3 OUTPUTS Timer 01 - Sun USERS www.amcelettronica.com KX series v.1.70...
  • Page 65 The exclusion periods can be associated precisely to the individual timers (of the 8 available for each day of the week) Each timer can have more than one period of exclusion. T01 - Mon 12345678 In the figure you can see that at timer no. 2 for Monday, 2 exclusion periods were associated, no. 1 and no. 3. www.amcelettronica.com KX series v.1.70...
  • Page 66 Once you have entered the menu, press ENTER to change Press ENTER again to enter the day of the week (1 for Mon, 2 for Tue...0 for Sun) Press the Right arrow to enter the day/month/year/hours/minutes in sequence Confirm with ENTER www.amcelettronica.com KX series v.1.70...
  • Page 67 2 << >> NO NEW Fig 3 When they have been read the red LED will turn off and the message in the figure will appear << EVENT >> #Exit fig 3 www.amcelettronica.com KX series v.1.70...
  • Page 68 For set the sequence, set the vector in numbering order, from 1 to 4, with verti- cal arrow select the number of order, with buttons 1 - 2 - 3 - 4 select the vector. GPRS Priority [03] Priority [04] PSTN www.amcelettronica.com KX series v.1.70...
  • Page 69 Contact ID response Wait This is the amount of the time the system waits for a response during a call before going on to the next one. It can be set from 1 to 50 seconds. www.amcelettronica.com KX series v.1.70...
  • Page 70 8000 ID monitor Number of identification system 12345678 Time between signals time monitor 1 min ademco system Id For each partition it is possible set a ID number: ID prg. 08 ID prg. 01 7788 1234 www.amcelettronica.com KX series v.1.70...
  • Page 71 Note: The reset activity is managed by the alarm cycled determined by the siren time. Therefore the shorter the siren time, the closer the notification of the resets. ademco - delay recovery With this parameter is possible to have the recovery zones after siren time: 0 = deactivated 1 = activated www.amcelettronica.com KX series v.1.70...
  • Page 72 The call is activated by pressing EN- ContactID PSTN/GSM TER and waiting for it to arrive. The event that is sent is always the life test(event no. 602) for CID and 4+2. TEST Ademco4+2 PSTN/GSM www.amcelettronica.com KX series v.1.70...
  • Page 73 This section regarding the test of SIA IP protocol with DC09 encod- ing. It’s possible test the GPRS and LAN module for sending. SIA IP GPRS/LAN TEST This section regarding the test of Ademco 4+2 protocol via PSTN and GSM with DTMF. PSTN/GSM ademco4+2 www.amcelettronica.com KX series v.1.70...
  • Page 74 KX series v.1.70...
  • Page 75 1 for enable.: Arm/disarm sound 0 SQUAWK alarm notification when disarm panel, the siren will notify with a low power sound and lamp flashing switch to 1 for enable.: Alarm memory 0 www.amcelettronica.com KX series v.1.70...
  • Page 76 This parameter enables the notification of radio disturbances. The notification is activated when there is a reception of a potentially dangerous radio signal for more than 5 seconds. Press ENTER to set the value (0=disabled, 1=enabled) Confirm with ENTER www.amcelettronica.com KX series v.1.70...
  • Page 77 When the control unit is in maintenance mode it will show on the display. Press ENTER set 1 to enable or 0 to disable * MAINTENANCE! * 14:30:15 www.amcelettronica.com KX series v.1.70...
  • Page 78 Open the soft db explorer and set the parameter of comunication remote programming, and Put the uiD CODe in the space tab. note: the uiD CODe must be copied from installer editor in the netWOrK menu --> ClOuD aCCOunt. Now it is possible change, send and get all setting from or to the panel. www.amcelettronica.com KX series v.1.70...
  • Page 79 - arm and disarm all partitions of panel - bypass all programmed zones - turn On and OFF all programmed output...
  • Page 80 (horizontal). It is possible to add and set in right position the zone and the output. Select the photo for each zone and outs. The app show when the zone is: ready: green circle open: orange circle alarm: red circle it is possible check and move programmed outs. www.amcelettronica.com KX series v.1.70...
  • Page 81 - PSTN line status - peripheral status - connection cables - wireless trouble In case of alarm it is possible receive notification with push technology (save battery life) In figure it is possible to see events and notification. www.amcelettronica.com KX series v.1.70...
  • Page 82 When the system is armed with bypassed zones, the type is armed will be FOrCeD in event log it is possible to see witch zone is bypassed and in witch way. www.amcelettronica.com KX series v.1.70...
  • Page 83 - quick event log menù - Pstn status - Gsm status - Battery status - main Power status - iP board internet status - GPrs board internet status - Cluod connection status - Firmware version - Hardware status www.amcelettronica.com KX series v.1.70...
  • Page 84 KX series v.1.70...
  • Page 85 APP and push in real time, the cloud is used for remote programming too. system name: is only the name of panel, in 1 app it is possible program more panels with diffrent name www.amcelettronica.com KX series v.1.70...
  • Page 86 The event that is sent is always the life test (event no. 602). It is possible test with all vectors, for each vector it is possible have feedback info. TEST ContactID PSTN/GSM TEST ContactID GPRS/Lan TEST Sia FSK PSTN TEST Sia IP GPRS/Lan TEST 4+2 PSTN/GSM www.amcelettronica.com KX series v.1.70...
  • Page 87 TEL.1=+393358554574 setting telephone number response from the system TEL.1:OK OUT.2=onoutput 2 activation response from the system OUT.:OK OUT.4=off deactivation of output 4 response from the system OUT.4:OK IN.2? input 2 status request response from the system IN.2=OP (if open) IN.2=CL (if at rest) www.amcelettronica.com KX series v.1.70...
  • Page 88 M16 = Line TEL.RECOV. M17 = FAULT Connection SYSTEM EVENTS M18 = ARM FAILED Play / record M19 = System Arming FAULT 230V M20 = Total Disarming *-View S- -S- - - M21 = Part. Ddisarming Credit Echo www.amcelettronica.com KX series v.1.70...
  • Page 89 Sirens Activat. 22222222222222222 Zones Menu [01] zone one Zones Delays Zones Menu [01] zone one AutoExclusion ●●●●●●●●●●●●●●● Zones Menu [01] zone one Unbypass ●●●●●●●●●●●●●●● Zones Menu I01/Tel 12345678 Telephones Link. *-Play S-S- - - - - www.amcelettronica.com KX series v.1.70...
  • Page 90 Key TOT -> It is possible link: REED Partitions-outs-led on keyfob D01-TR800 Nr.01 D01-TR800 Nr.01 D01-CU400 Nr.01 Key TOT -> 1234 D01-CU400 Nr.01 D01-CU400 Nr.01 Replacing SWITCH D01-CU400 Nr.01 Erasing D01-CU400 Nr.01 Replacing D01-CU400 Nr.01 Erasing www.amcelettronica.com KX series v.1.70...
  • Page 91 00/00 00/00 USERS - - - - - - - - - - - - - - - - Period 08 00/00 00/00 TIMERS T01-Sun 12345678 Enable Exclusion ●●●●●●●● T04-Sat 12345678 ●●●●●●●● TIMERS Alert (Min) 0 www.amcelettronica.com KX series v.1.70...
  • Page 92 Reset Ongoing Reset Completed Events Memory Wait... # Exit MENU EDIT VOCABLES Voc. Num. [001] Edit Vocables Vocables list masking Voc. Num. [009] alarm EDIT VOCABLES WORD NUM [001] ONLY X series Audio message *-PLAY x-REC www.amcelettronica.com KX series v.1.70...
  • Page 93 CONNECT FAILURE Link Phones 4+2 ●●●●●●●● DISARMED BY PRS INPUT FAILURE [80] ADEMCO AUTOARM.FAILED Max Attempts AMRMING FAILED [90] PANIC ADEMCO [01] zone 1 [A0] Zone Recovery PANIC RECOVERY [64] zone 64 ADEMCO [B0] Delay Recovery www.amcelettronica.com KX series v.1.70...
  • Page 94 Cloud Account Enabled USER NAME Administrator PASSWORD admin SYSTEM NAME example K8 + UID CODE NOTIFICATIONS NETWORK Alarms Cloud notificat. NOTIFICATIONS Users NOTIFICATIONS Arm/Disarm NETWORK ENABLE GPRS Gprs parameters ACCESS POINT USER NAME APN PASSWORD APN www.amcelettronica.com KX series v.1.70...
  • Page 95 OTHER PARAMETERS No220 (min) OTHER PARAMETERS Battery Charge OTHER PARAMETERS Self-Excl. OTHER PARAMETERS LIFETEST Life Test Start Hour 00:00 OTHER PARAMETERS LIFETEST ONLY X series speakerphone 00 d 00 hr OTHER PARAMETERS Quick Arming OTHER PARAMETERS Maintenance www.amcelettronica.com KX series v.1.70...
  • Page 96 Keys up and down for activate and deactivate ACTIVATE [01] output one OUTPUTS 0 1 0 0 - - - - - - - - - - www.amcelettronica.com - = Not programmed KX series v.1.70 0 = Deactivate down 1 = Activate...
  • Page 97 ContactID PSTN TEST SIA Ip GPRS TEST ContactID GSM TEST TEST SIA Ip LAN ContactID GPRS TEST TEST Ademco4+2 PSTN ContactID LAN TEST Ademco4+2 GSM DATA HOUR Sun 01/01/00 Settings 08:00:00 DATA HOUR MENU Summer Time DATE/HOUR www.amcelettronica.com KX series v.1.70...
  • Page 98 SPECIFICATIONS IP BOARD ..............................26 XGPRS MODULE .................................. 27 INSTALLATION ON PANEL ..............................27 IP1 BOARD DESCRIPTION..............................28 SPECIFICATIONS XGPRS BOARD ............................28 LED DESCRIPTION ................................28 CONNECTIONS - SERIAL BUS ............................... 29 CONNECTIONS - SIRENS ..............................29 www.amcelettronica.com KX series v.1.70...
  • Page 99 MENU OF OUTPUTS: DELAY ..............................54 MENU OF OUTPUTS: POLARITY ............................54 MENU OF OUTPUTS: AUTORESET ............................54 MENU OF OUTPUTS: OPERATING CONDITIONS ........................55 MENU OF OUTPUTS: TELEPHONES LINK..........................55 MENU OF OUTPUTS: USERS LINK ............................55 www.amcelettronica.com KX series v.1.70...
  • Page 100 MENU OTHER PARAMETERS ..............................74 OTHER PARAMETERS: SIREN SETTINGS..........................74 SIREN SETTINGS: SIREN DURATION ............................74 SIREN SETTINGS: SIREN PAUSE ............................. 74 SIREN SETTINGS: SIREN CYCLES ............................74 SIREN SETTINGS: SIREN TO KEYPAD............................74 SIREN SETTINGS: SQUAWK FUNCTION ..........................74 www.amcelettronica.com KX series v.1.70...
  • Page 101 OTHER PARAMETERS: LIFE TEST ............................76 OTHER PARAMETERS: QUICK ARMING ..........................76 OTHER PARAMETERS: MAINTENANCE ..........................76 PROGRAMMING PANEL WITH SOFTWARE ..........................77 AMC AMANAGER APP ................................. 78 REGISTER APP ..................................78 ADD PANEL TO THE APP ............................... 79 TROUBLES AND STATUS INFO ............................... 80 HOW TO USE THE SYSTEM (USER MANUAL) .........................
  • Page 102 TECH KEYPAD MENU - 8 ..............................94 USER KEYPAD MENU - 1 ..............................95 USER KEYPAD MENU - 2 ..............................96 www.amcelettronica.com KX series v.1.70...

Table of Contents