ademco network parameters

When the event is enabled, there are the network settings:
IP/domain [01]
192.168.1.1
IP/domain [02]
192.168.1.1
Port num.
10000
Port num.
10001
Protocol
Tcp/Udp
Protocol
Tcp/Udp
Encoding
dc09 CID
Data session
(sec.)
Phone SMS
Backup

ademco network monitor

The monitor, is a special signal that is used for life test of the IP connection between the monitoring station.
This signal can be sent directely on special database soft, or in IT GPRS RX.
IP/domain
192.168.1.1
Port Number
8000
ID monitor
12345678
time monitor

ademco system Id

For each partition it is possible set a ID number:
ID prg. 01
1234
www.amcelettronica.com
IP address of monitoring station receiver n°1
IP address of monitoring station receiver n°2
[01]
Port number of first IP number
Port number of second IP number
[02]
Protocol type TCP or UDP
[01]
Protocol type TCP or UDP
[02]
Type of encoding:
- select 0 for set: IT GPRS RX
- select 1 for set: DC09 CID
- select 2 for set: DC09 SIA
IT gprs RX is a proprietary protocol, and needs the HW receiver in monitoring station.
DC09 CIDand SIA is a standard IP protocol.
This parameter mean that the max time for sending/contact the receiver, is needed for
close the comunication in case of error from receiver.
60
this is a special number that is used in IT GPRS RX for IP backup, in case of fault
comunication via IP, the system will send the SMS.
IP address of monitoring station receiver
Port number of receiver
Number of identification system
Time between signals
1 min
ID prg. 08
7788
70