9.
Install the vent plug and sealing washer.
10. Continue to pump gear lube into the drive through the fill and drain plug hole until the gear lube appears in the gear lube
monitor.
11. Fill the gear lube monitor so that the gear lube level is in the operating range. Do not overfill.
c
a
Sterndrive Model
Bravo One X Diesel
Bravo One XR
Bravo Three X Diesel
Bravo Three XR
12. Ensure that the rubber gasket is inside the gear lube monitor cap and install. Do not overtighten.
a
13. Remove the pump from the sterndrive fill and drain plug hole.
Page 42
b
Fluid Capacity includes
the Sterndrive and the
Gear Lube Monitor
2736 ml (92‑1/2 oz)
2972 ml (100‑1/2 oz)
a -
Gear lube monitor cap
19962
Gear lube monitor
a -
Gear lube level at the "ADD" mark
b -
Gear lube level at the "OPERATING RANGE" mark
c -
Gear lube monitor cap
19947
Fluid Type
High Performance Gear
Lube
90-8M0114081
Fluid Part Number
92‑802854A1
DECEMBER 2015