Installation - Viessmann Vitosol 100 Installation Instructions Manual

Type s2.5 flat solar panels for pitched roofs, installation on top of roofs
Hide thumbs Also See for Vitosol 100:
Table of Contents

Advertisement

Installation

¨ Safety instructions
Use only gunmetal and brass fittings and copper pipes for the installation.
Never use galvanized pipes, galvanized fittings or graphitised gaskets. Use
hemp only in conjunction with pressure and temperature resistant sealants
(e.g. Viscotex Solarpaste, Locher & Co. AG, CH 9450 Altstätten).
Never step onto solar panels. Never solder near or on the collector.
L
A Collector
B Solar Divicon
C Collecting container
D Expansion vessel
E Manual solar filling pump
F Filling point
G Shut-off valve
22
M
T
N
G
H
F
E
K
H Drain
K Fill valve (F , G, H)
L DHW cylinder
M Air separator
N Solar control unit
O Air vent valve
P Flow regulating valve
O
T
B
T
T
P
D C
A

Advertisement

Table of Contents
loading

Table of Contents