Summary of Contents for REMKO RKV 13 C

  • Page 1: Spare Parts

    REMKO RKV 13 C / 18 C / 24 C Ceiling Cassettes Operation Technology Spare Parts REMKO – powerful like a bear. Edition GB – P05...
  • Page 3: Table Of Contents

    Subject to alterations! Indoor units for room air-conditioning systems Ceiling cassettes REMKO RKV 13 C / 18 C / 24 C Contents Contents Page...
  • Page 4: Safety Hints

    (surrounding temperatures). The environmentally-friendly refrigerant R 407C trans- à Make sure that the unit is kept at a safe distance ports this warmth just as it does for all other REMKO from flammable objects. air-conditioning products. à Do not install the air-conditioning unit close to heat- The unit’s primary function is to air-condition rooms.
  • Page 5: Operation

    Operation à When transmitting data, the distance between the transmitter and receiver may not exceed 5 m. Inserting the batteries Prior to initial operation, the batteries supplied with the unit (2 type AAA batteries) must be inserted into the re- B E E P mote control.
  • Page 6 Yellow light (timer signal) The remote control It lights up if the timer is activated. It blinks after a power outage, e.g. after the power sup- ply has been interrupted or if the unit was restarted right after being switched off in timer mode. Green light (ON / OFF signal) It lights up when the unit is in operation.
  • Page 7 Checking signal transmission Setting the clock - Button 19 Point the remote control at the receiver of the indoor To use the Timer program, you must set the clock on unit. Press the ON/OFF button once. The air- the remote control beforehand. conditioning unit now indicates proper reception by To do this, the button (19) must be pressed and held...
  • Page 8 Operating mode button (6) Optimum dehumidification mode In “Dehumidification” mode, the air in the room is suc- There are 3 operating modes available for using the tioned in by the air-conditioning unit at periodic intervals, ceiling cassettes. The operating mode button can be filtered and returned to the room in a slightly cooled used to program the following functions: state.
  • Page 9 In cooling mode, the plate fins should be in a “half open” Air distribution button (13) position (see figure below) or the oscillating mode The ceiling cassette has 4 air outlet openings to distrib- should be selected. ute the cooled air in the room. Air outlet plate fins Stream of air to the ceiling Air outlet plate fins...
  • Page 10 Timer on button (14) à If the timer function is activated, the unit checks the room temperature one hour before the programmed A timed program can be set and activated for unit op- start-up time. Based on the start-up time, the unit eration with the (14) button.
  • Page 11 3. Press down the buttons (6) and (13) on the re- Night shut-down button (17) mote control for 5 seconds. The night shut-down function is a convenient function The display is deleted. The temperature display that lets the room temperature rise gradually which has shows the present value of this configuration entry health benefits.
  • Page 12: Maintenance And Service

    Maintenance and Service Address selection display If there are two indoor units installed in a room and if Regular care and the observation of a number of basic they are to be operated independently of one another, rules will ensure the unit’s long service life and reliable each unit must have its own address assigned so that it operation.
  • Page 13: Shutting Down The Unit

    For the guarantee to be valid, the purchaser or his cus- and pull the filter out. tomer must completely fill out the "guarantee certificate" enclosed with all units and send it back to REMKO GmbH & Co. KG The units are repeatedly tested at the production site to ensure that they are working properly.
  • Page 14: Technical Data

    Technical Data RKV 13 C RKV 18 C RKV 24 C See outdoor part 4800 6800 Cooling capacity R 407 C R 407 C R 407 C Refrigerant Operating range °C +17 °C to + 32 °C in 1 °C increments...
  • Page 15: Troubleshooting

    Should the unit still not work after performing these functional checks, please contact the closest dealer or REMKO GmbH & Co KG. directly. See also section “Customer Service and Guarantee”.
  • Page 16: Assembly Instructions For Service Personnel

    Assembly Instructions for à The air intake and outlet openings may not be blocked by furniture, curtains, etc. Service Personnel à Prevent unnecessary bends in the refrigeration lines to minimise the pressure loss and ensure that the Important instructions prior to installation compressor oil can recirculate properly.
  • Page 17: Installation

    Installation Assembling the connection line The indoor unit is attached by means of four threaded 1. Position the cassette in such a way that all sides are rods to be provided by the customer. The supplied card- freely accessible. board stencil makes it easier to position the holes to drill. To ensure the best air distribution in the room, the indoor unit should be installed in the middle of the Assembly material...
  • Page 18 11. Now tighten the bolts using 2 hexagonal wrenches We recommend using a two-speed vacuum pump with that have a large enough opening. an absolute final partial pressure of at least 0.01 mbar at a pump capacity of a min. of 1.5 m³/h. 12.
  • Page 19: Condensation Connection

    Condensation Connection Connecting the RKV 13 C indoor unit = External conductor power supply indoor unit Condensation forms on the evaporator during cooling operation because temperatures below the dew point N = Neutral conductor power supply indoor unit are reached. The collection tray of the indoor unit is = Control conductor to outdoor part (compr.
  • Page 20 Wiring diagram RKV 13 C Transformer Plate fin motor and Main board micro plate fin switch = External conductor = Neutral conductor = Compressor operation (relay) = No function LED / IR W2 = No function connection When connecting to RKS:...
  • Page 21: Two-Room And Fresh Air Connection

    Two-Room and Fresh Air Installing the two-room connection Connection The indoor unit is designed to cool a second room and, independently of this, to suction in fresh air. On each side of the unit, there is a pre-punched open- ing of Ø 150 mm across from one another for connec- tion to a second room and a pre-punched opening on the corner of the unit for the fresh air connection.
  • Page 22: Prior To Initial Operation

    3. Connect the unit to the power supply and switch the Installing the air direction plate power on. To provide cool fresh air to the room, it is necessary to 4. Press down the buttons (9) and (13) of the re- mount the supplied air direction plate made of plastic.
  • Page 23: Certification For Initial Operation

    Certification for Initial operation Subsequent operation of a REMKO air-conditioning unit / system Unit data according to type plate Outdoor part Indoor unit 1 Indoor unit 2 Indoor unit 3 Unit type: Unit number: Setup location: Set up by: Name:...
  • Page 24 REMKO GmbH & Co. KG Klima- und Wärmetechnik D-32791 Lage Im Seelenkamp 12 • D-32777 Lage PO Box 1827 • Phone +49 (5232) 606 - 0 +49 (5232) 606260 E-Mail: info@remko.de Internet: www.remko.de...