Wiring Error Check Unexecuted - Daikin CTXG09QVJUW Service Manual

Multi-split type air conditioners 2/3/4mxs-n series
Hide thumbs Also See for CTXG09QVJUW:
Table of Contents

Advertisement

SiUS121630EA
7.3

Wiring Error Check Unexecuted

U3
Error Code
Outdoor Unit LED
A
Display
Method of Error
The system checks if wiring error check is executed after clearing the memory.
Detection
Error Decision
An error is determined when the unit is operated by the remote controller without executing wiring
error check after the memory was cleared.
Conditions
Supposed
The wiring error switch (SW3) may have been pressed for 10 seconds or more and the memory
may have been deleted. The unit cannot be operated unless wiring error check is executed.
Causes
Troubleshooting
Note:
Refer to wiring error check on page 205 for details.
Service Diagnosis
j
h
i
h
h
1
2
3
4
Be sure to turn off the power switch before connecting or disconnecting
Caution
connectors, or parts may be damaged.
Wiring error check
executed?
YES
h
5
NO
Troubleshooting for Outdoor Unit
Conduct wiring error check.
Wiring error check may not
have been finished because of
the trouble of indoor/outdoor
unit.
Conduct wiring error check
again.
(R23952)