Daikin CTXG09QVJUW Service Manual page 137

Multi-split type air conditioners 2/3/4mxs-n series
Hide thumbs Also See for CTXG09QVJUW:
Table of Contents

Advertisement

SiUS121630EA
3.1.2 ARC466 Series Remote Controller
1. When Timer Cancel button is held down for 5 seconds, 00 is displayed on the temperature
Method 1
2. Press Timer Cancel button repeatedly until a long beep sounds.
ARC466A21, A36
Notes:
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold down Timer Cancel button for 5 seconds. When the remote
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
Service Diagnosis
display screen.
Timer Cancel button
The code indication changes in the sequence shown below.
No.
Code
00
1
A5
2
E7
3
F3
4
F6
5
L3
6
L4
7
L5
8
U4
9
E6
10
H6
11
H0
12
A6
13
controller is left untouched for 60 seconds, it also returns to the normal mode.
(→ Refer to page 126.)
< ARC466 Series >
No.
Code
U0
14
C7
15
A3
16
H8
17
H9
18
C9
19
C4
20
C5
21
J3
22
J6
23
E5
24
A1
25
E1
26
Service Diagnosis
(R24045)
No.
Code
UA
27
UH
28
P4
29
H7
30
U2
31
EA
32
AH
33
FA
34
H1
35
P9
36
E3
37
H3
38
125