Lsg Mark Ii Low Pressure Using 350Lb. Liquid C02 Tank - Ultratec G3000 Operator's Manual

Lsg mark ii
Hide thumbs Also See for G3000:
Table of Contents

Advertisement

LSG Mark II Low Pressure using 350lb. liquid C02 tank

These instructions are given for systems using a G3000 with LSG Control Option. Alternate control options are
given further in this manual.
1. Place the G3000 output directly against the foam ring input of the LSG Mark II.
TECH TIP: Proper alignment can be observed by shining a flashlight into the 10" exit of the LSG Mark II and
noting the G3000 output nozzle is centered in the LSG Mark II input.
2. Connect the blue Twist lock connector from the LSG Mark II into Custom port on the rear panel of the fog
machine.
3. Power up the G3000 by turning on the power switch.
NOTE:
Detailed G3000 operating instructions located in G3000 Operators Manual
LSG PRE-FOG TIME
0:00 (mm:ss)
DMX Address: 511
Data 0 D+1 0
NOTE: This delay allows the liquid CO2 to purge the supply hose of CO2 gases ensuring only liquid is
available for optimum cooling. The recommended formula for calculating delay time is 1 sec. for every
three feet of supply hose.
4. Adjust the remote flow rate to desired fog output level. It is recommended to start at 50% and adjust
accordingly. The maximum recommended flow for the LSG Mark II Low is 75%.
5. An LSG Mark II Low requires a 350 lb. Low Pressure Liquid CO2 Tank. You must connect the supply hose to the
Liquid output of the Liquid CO2 Tank. This is usually clearly indicated on the Liquid CO2 Tank outputs.
6. The second connection to be made is the CO2 supply hose. This is connected to the liquid port of the CO2
supply.
7. A fibre washer is necessary to prevent leaks and are available from your gas supplier.
8. Tighten the CO2 supply fitting snug with appropriate wrench.
9. The Liquid CO2 Tank pressure as indicated on the pressure gauge must read between 300-340 psi to operate
the LSG Mark II, this is achieved by opening the pressure builder valve at least one to three hours in advance of
use by turning counter clockwise.
8
www.ultratecfx.com
0-255
When connected to an LSG, set the desired
time for the LSG to inject C02 before the
G3000 begins to produce fog.
(0-2 Minutes)
Using the "+" or "-" buttons select the
desired valid DMX address. (0-511)
Data = fog rate controlled 0-100%,
DMX+1=LSG power on above 50%.
0-255
128 - Relay