Minimum System Requirements
Operating System
Processor
Memory
Hard Drive
Video
Network
Pointing Device

05.6 Network Interface

The ProJet™ Production Printing System requires an Ethernet network connection to transfer print jobs from workstation(s) to the printer.
Network Specifications, Physical: The machine's internal controller provides an integrated, 10/100-megabit-per-second (Mbps) Ethernet
network connection. This connection supports both the 10base-T and 100base-TX Ethernet standards. The controller's connector (an RJ45
socket located on the back panel) is designed for attaching a shielded twisted pair (UTP) Ethernet cable.
When a facility's internal network is not 10base-T or 100base-TX, a media converter, such as a Coax to 10base-T will be required. Consult with
your organization's network engineering or MIS staff to provide assistance with these requirements.
The printer works on networks running TCP/IP ONLY each printer MUST have a STATIC IP address on the network. Additionally, each printer's
subnet mask and default gateway must be known and available to 3D Systems' 3D Systems Field Service Engineer or authorized reseller at the
time of its installation, and should also be known by personnel installing the client software. They will need access either to the appropriate subnet
mask or the individual IP address of each printer to complete the workstation software installation, and to enable access to any printer on the
network.
Not all networks have the TCP/IP installed. Make sure to have a network administrator check that TCP/IP are both installed
and are running as required PRIOR TO THE ARRIVAL of the printer.

05.7 Material Storage

VisiJet® part and support materials should uie stored in a conveniently located storage cabinet in proximity to the printer itself. A cabinet is
recommended to protect against long term exposure to external UV light sources, including sunlight, overhead lighting, or other UV light sources.
Storage temperature of the material should not exceed the specified maximum of 35°C (95°F)
from strong oxidizing agents, such as hydrogen peroxide, bromine, or chromic acid.
NOTE: When storing material bottles that have been used but still have materials in
the bottles, do not lay the bottles on their side in storage. Store box with side
spacers installed. *DO NOT rest on nose of bottle. Also, in the case where used bottles
with materials are removed from the MDM and are still warm, it must be stored with the
cap vented. If the warm bottle is not vented, the wax will contract during cooling and the
bottle's bottom may become flat which will prevent reengagement in the MDM.*
More detailed information on the VisiJet® build material and VisiJet® support material, relevant applicable safety precautions and remediation,
and specific storage and disposal requirements, can be found in the
(or equivalent) should maintain a copy of the two MSDS documents, and provide ready, convenient access to these documents. To obtain the
VisiJet material MSDS from 3D Systems, click here
Hotline within the U.S. at (800) 793-3669 (or from outside the U.S.A. at +49 (0) 6151 357357, or by visiting
Windows XP/Windows Vista/ Windows 7
Intel® Pentium® 4 Processor
1 GB RAM
4 GB free space
Graphics adaptor with OpenGL 3D acceleration, true color at 1024x768 resolution
Ethernet network infrastructure with TCP/IP protocol
Two-button mouse
for additional copies. If further information is needed, please contact 3D Systems' Customer
Material Safety Data Sheet (MSDS)
. VisiJet® part material should be stored away
. Your organizations' Facilities Manager
3D Systems website
.

Advertisement

Table of Contents
loading

Table of Contents