Digital Switch

When DSW instructions are used
Examples of wiring for capturing values from a 4-digit digital switch to the data register D100 are given below.
For the instructions, refer to MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks).
■Example of program
SM400
DSW
X010
Y010
■Example of wiring
• Sink wiring
The example is the wiring for the input/output of the FX5U-32MT/ES.
Digital
switch of
BCD
0.1A 50V
diode is
necessary.
S/S
0V
24V
• Source wiring
The example is the wiring for the input/output of the FX5U-32MT/ESS.
Digital
switch of
BCD
0.1A 50V
diode is
necessary.
S/S
0V
24V
D100
K1
0
1
10
10
1
2
4
8
X010 X011 X012 X013
Sink input
Transistor output (sink)
COM2 Y010 Y011 Y012 Y013
0
1
2
3
10
10
10
10
0
1
10
10
1
2
4
8
X010 X011 X012 X013
Source input
Transistor output (source)
+V2 Y010 Y011 Y012 Y013
0
1
2
3
10
10
10
10
2
3
10
10
X014
X015
X016 X017
FX5U-32MT/ES
2
3
10
10
X014
X015
X016 X017
FX5U-32MT/ESS
6.8 Examples of Wiring for Various Uses
6
6 WIRING
105