For a pumping unit (pump, seal, coupling, motor and
pump accessories) to be certified for use in an ATEX
classified environment, the proper ATEX identification
must be present.
The ATEX tag will be secured to the pump or the
baseplate on which it is mounted. A typical tag will look
like this:
The CE and the EX designate the ATEX compliance.
The code directly below these symbols reads as follows:
II
= Group 2
2
= Category 2
G/D
= Gas and Dust present
T"x"
= Temperature class, can be T1 to T6
(see Table 1)
The ATEX conformance is only applicable when the
pump unit is operated within its intended use. All
instructions within this manual must be followed at all
times. Operating, installing or maintaining the pump unit
in any way that is not covered in this manual can cause
serious personal injury or damage to the equipment.
For assistance in selecting the proper instrumentation and
its use, please contact your ITT/Goulds representative.
!
When installing in a potentially explosive
environment, ensure that the motor is properly
certified.
3996 IOM 9/2010
ATEX IDENTIFICATION

INTENDED USE

CONDITION MONITORING
Table 1
Code
Max permissible
surface temperature
F (
C)
o
o
T1
842 (450)
T2
572 (300)
T3
392 (200)
T4
275 (135)
T5
212 (100)
T6
185 (85)
The code classification marked on the equipment should
be in accordance with the specified area where the
equipment will be installed. If it is not, please contact
your ITT/Goulds representative before proceeding.
E
This includes any modification to the equipment or use of
parts not provided by ITT/Goulds. If there is any
question regarding the intended use of the equipment
please contact an ITT/Goulds representative before
proceeding.
G
!
For additional safety precautions, and where noted
in this manual, condition monitoring devices
should be used. This includes, but is not limited
to:
·
Pressure gauges
·
Flow meters
·
Level indicators
·
Motor load readings
·
Temperature detectors
·
Bearing monitors
·
Leak detectors
·
PumpSmart control system
Max permissible
1
liquid temperature
F (
C)
o
o
700 (372)
530 (277)
350 (177)
235 (113)
Option not available
Option not available
11