What is Hub Site Synchronization?
Figure 7-1: Interference caused by collocated units
Adding HSS removes interference as shown in the next two figures:
Figure 7-2: Collocated units using Hub Site Synchronization (1)
Figure 7-3: Collocated units using Hub Site Synchronization (2)
The units are connected to each other with HSS cables and HSS Distribution Units.
One of the radios in the site is defined as HSS Master and generates synchronization pulses.
The other collocated radios in the site - the HSS Clients, are connected to the HSS Master and
synchronize their transmission to the pulses. An HSS Client can be configured to work in one
of two modes: