Table 7-5 External Pulse - Radwin RW-5200-0250 User Manual

5000 hbs, 5000 hsu, idu (poe) point to multipoint broadband wireless
Table of Contents

Advertisement

Sector Configuration and HSS
Figure 7-12: HBS as HSM
The possible External Pulses conditions are shown in the following table:
Table 7-5: External Pulse Status
HSS Sync Status
Generating
Detected
Not detected
Generating and detected
Generating and
Improperly Detected
Not detected
Improperly detected
RADWIN 5000 HPMP User Manual
Meaning
ODU is HSM and generates the
sync pulse
ODU is HSC and detects the
sync pulse
ODU is independent
HSM, but other HSM present
RADWIN 2000 ODU is HSM,
but detects a WinLink 1000
HSM signal that is not RFP E
HSC but no HSM present
HSC but HSM pulse doesn't fit
the HSC as configured. Occurs
only for RADWIN 2000, which
stops transmitting.
Release 3.1.00
Color code
Green
Orange
Red
Chapter 7