Nibe F1355 Operating Manual page 26

Ground source heat pump
Hide thumbs Also See for NIBE F1355:
Table of Contents

Advertisement

Set the lower tariff periods. It is possible to set two dif-
ferent date periods per year. Within these periods, it is
possible to set up to four different periods on weekdays
(Monday to Friday) or four different periods on weekends
(Saturdays and Sundays).
Menu 4.2 - op. mode
op. mode
Setting range: auto, manual, add. heat only
Default value: auto
functions
Setting range: compressor, addition, heating, cooling
The heat pump operating mode is usually set to "auto".
It is also possible to set the heat pump to "add. heat
only", but only when an addition is used, or "manual"
and select yourself what functions are to be permitted.
Change the operating mode by marking the desired
mode and pressing the OK button. When an operating
mode is selected, it shows what is permitted in the heat
pump (crossed out = not permitted) and selectable al-
ternatives to the right. To select selectable functions that
are permitted or not, mark the function using the control
knob and press the OK button.
Operating mode auto
In this operating mode the heat pump automatically
selects what functions are permitted.
Operating mode manual
In this operating mode you can select what functions
are permitted. You cannot deselect "compressor" in
manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active, only
additional heat is used.
Caution
If you choose mode "add. heat only" the com-
pressor is deselected and there is a higher oper-
ating cost.
Functions
"compressor" is that which produces heating and hot
water for the accommodation. If "compressor" is
deselected, a symbol in the main menu on the heat pump
symbol is displayed. You cannot deselect "compressor"
in manual mode.
"addition" is what helps the compressor to heat the ac-
commodation and/or the hot water when it cannot
manage the whole requirement alone.
"heating" means that you get heat in the accommoda-
tion. You can deselect the function when you do not
wish to have heating running.
26
Chapter 3 |
Control - Menus
"cooling" means that you get cooling in the accommod-
ation in hot weather. You can deselect the function when
you do not wish to have the cooling running. This altern-
ative requires the accessory for cooling to be installed
and activated.
Caution
If you deselect "addition" it may mean that suf-
ficient heating in the accommodation is not
achieved.
Menu 4.3 - my icons
You can select what icons should be visible when the
door to F1355 is closed. You can select up to 3 icons. If
you select more, the ones you selected first will disap-
pear. The icons are displayed in the order you selected
them.
Menu 4.4 - time & date
Set time and date, display mode and time zone here.
TIP
Time and date are set automatically if the heat
pump is connected to NIBE Uplink. To obtain
the correct time, the time zone must be set.
Menu 4.6 - language
Choose the language that you want the information to
be displayed in here.
Menu 4.7 - holiday setting
To reduce energy consumption during a holiday you can
schedule a reduction in heating and hot water temper-
ature. Cooling, ventilation, pool and solar panel cooling
can also be scheduled if the functions are connected.
If a room sensor is installed and activated, the desired
room temperature (°C) is set during the time period. This
setting applies to all climate systems with room sensors.
If a room sensor is not activated, the desired offset of
the heating curve is set. One step is usually enough to
change the room temperature by one degree, but in
some cases several steps may be required. This setting
applies to all climate systems without room sensors.
Vacation scheduling starts at 00:00 on the start date and
stops at 23:59 on the stop date.
TIP
Complete holiday setting about a day before
your return so that room temperature and hot
water have time to regain usual levels.
TIP
Set the vacation setting in advance and activate
just before departure in order to maintain the
comfort.