Nibe F1355 Operating Manual page 24

Ground source heat pump
Hide thumbs Also See for NIBE F1355:
Table of Contents

Advertisement

2. Mark "server" and press the OK button.
3. Enter the correct details via the virtual keypad.
4. Mark "OK" and press the OK button.
5. Repeat 1 - 3 for "port", "user name" and "password".
6. Mark "confirm" and press the OK button.
TIP
All settings made since opening the menu can
be reset by marking "reset" and pressing the OK
button.
Menu 4.1.4 - sms (accessory is required)
Make settings for the accessory SMS 40 here.
Add the mobile numbers that are to have access to
change and receive status information from the heat
pump. Mobile numbers must include country code e.g.
+46 XXXXXXXX.
If you want to receive an SMS message in the event of
the alarm mark the box to the right of the telephone
number.
NOTE
Telephone numbers provided must be able to
receive SMS messages.
Menu 4.1.5 - SG Ready
This function can only be used in mains networks that
support the "SG Ready"-standard .
Make settings for the function "SG Ready" here.
affect room temperature
Here you set whether room temperature should be af-
fected when activating "SG Ready".
With low price mode on "SG Ready" the parallel offset
for the indoor temperature is increased by "+1". If a room
sensor is installed and activated, the desired room tem-
perature is instead increased by 1 °C.
With over capacity mode on "SG Ready" the parallel
offset for the indoor temperature is increased by "+2".
If a room sensor is installed and activated, the desired
room temperature is instead increased by 2 °C.
affect hot water
Here you set whether the temperature of the hot water
should be affected when activating "SG Ready".
With low price mode on "SG Ready" the stop temperat-
ure of the hot water is set as high as possible at only
compressor operation (immersion heater not permitted).
With over capacity mode of "SG Ready" the hot water is
set to "luxury" (immersion heater permitted).
affect cooling (accessory required)
Here you set whether room temperature during cooling
operation should be affected when activating "SG
Ready".
With low price mode of "SG Ready" and cooling opera-
tion the indoor temperature is not affected.
24
Chapter 3 |
Control - Menus
With over capacity mode on "SG Ready" and cooling
operation, the parallel offset for the indoor temperature
is reduced by "-1". If a room sensor is installed and activ-
ated, the desired room temperature is instead reduced
by 1 °C.
affect pool temperature (accessory is required)
Here you set whether pool temperature should be af-
fected when activating "SG Ready".
With low price mode on "SG Ready", the desired pool
temperature (start and stop temperature) is increased
by 1 °C.
With over capacity mode on "SG Ready" the desired pool
temperature (start and stop temperature) is increased
by 2 °C
Menu 4.1.6 - Smart price adaption™
activated
This function can only be used if you have an hourly
tariff agreement with your electricity supplier that
supports Smart price adaption™ and you have an ac-
tivated NIBE Uplink account.
area
Here you select where (which zone) the heat pump
is set-up.
Contact your electricity supplier to find out which
zone digit to enter.
affect room temperature
Setting range: 1 - 10
Factory setting: 5
affect hot water
Setting range: 1 - 4
Factory setting: 2
affect pool temperature
Setting range: 1 - 10
Factory setting: 2
affect cooling
Setting range: 1 - 10
Factory setting: 3
price of electricity overview
Here you can obtain information on how the electri-
city price varies over up to three days.
In menu Smart price adaption™ you state where the
heat pump is located and how great a role the electricity
price should play. The greater the value, the greater the
effect the electricity price has and the larger the possible
savings, but at the same time there is an increased risk
of affecting comfort.