Nibe F1355 Installer Manual

Nibe F1355 Installer Manual

Ground source heat pump
Hide thumbs Also See for F1355:

Advertisement

Installer manual
NIBE F1355
Ground source heat pump
IHB EN 1741-3
331996

Advertisement

Table of Contents
loading

Summary of Contents for Nibe F1355

  • Page 1 Installer manual NIBE F1355 Ground source heat pump IHB EN 1741-3 331996...
  • Page 3: Table Of Contents

    6 Commissioning and adjusting Preparations Filling and venting Start guide Post adjustment and venting 7 Accessories 8 Technical data Dimensions and setting-out coordinates Technical specifications Energy labelling Electrical wiring diagram, 3x400V 28 kW Item register Contact information NIBE F1355 Table of Contents |...
  • Page 4: Important Information

    EU, regardless of where they are made. This is an original manual. It may not be IP21 Classification of enclosure of electro-technical translated without the approval of NIBE. equipment. Rights to make any design or technical Danger to person or machine.
  • Page 5 Cut the power before starting electrical work. - When filling refrigerant, the refrigerant must always leave the Failure to cut the power can cause electric shocks, damage and in- bottle in liquid form. correct function of the equipment. NIBE F1355 Chapter 1 | Important information...
  • Page 6 Kyoto agreement. F-Gas Regulation (EU) No. 517/2014 The equipment contains R407C, a fluorinated green- house gas with a GWP value (Global Warming Potential) of 1,774. Do not release R407C into the atmosphere. Chapter 1 | Important information NIBE F1355...
  • Page 7 Filterball (particle filter) Safety valve Shut off valves Circulation pumps set Electricity (page 20) Connections Main voltage Phase voltage Fuses heat pump Fuses property Outside sensor Room sensor Current sensor Safety breaker Earth circuit-breaker NIBE F1355 Chapter 1 | Important information...
  • Page 8 Description Notes Signature Date ✔ Relay output for emergency mode Chapter 1 | Important information NIBE F1355...
  • Page 9: Delivery And Handling

    (and any routing of supply cables and pipes) to reduce the risk of any vibra- F1355 must be lifted on the heaviest side and can be tion being propagated. moved on a sack truck. Two people are required to lift F1355.
  • Page 10: Supplied Components

    The enclosed kit is placed in the packaging next to the 2. Twist the cover slightly outward. heat pump. 3. Move the hatch outwards and backwards. 4. Assembly takes place in the reverse order. Chapter 2 | Delivery and handling NIBE F1355...
  • Page 11: The Heat Pump Design

    -GP16 AA101-XJ2 AA101-X3 AA101-X5 AA101-X7 AA101-X9 AA3-X21 AA3-X23 EP15-XL7 EP15-XL1 AA4-XJ4 EP15-XL6 EP15-XL2 AA4-XJ3 EP15 EP15-PF2 EP14-XL7 EP14-XL1 XJ10 EP14-XL6 EP14-XL2 EP14-PF2 EP14 XJ11 AA26 AA27 AA101-X2 XJ10 AA23 AA101-X1 AA101 NIBE F1355 Chapter 3 | The heat pump design...
  • Page 12: Distribution Boxes

    Connector, electrical supply to compressor, cooling module -EP14 AA101-XJ2 Connector, electrical supply to compressor, cooling module -EP15 Compressor heater -EP14 Connector, brine pump, cooling module Connector, heating medium pump, cooling module Compressor heater-EP15 Chapter 3 | The heat pump design NIBE F1355...
  • Page 13: Cooling Section

    Cooling components AA100 Evaporator Condenser GQ10 Compressor BT10 Drying filter Expansion valve Designations in component locations according to BT11 standard IEC 81346-1 and 81346-2. BT14 GQ10 BT17 BT15 XL21 EB10 XL20 NIBE F1355 Chapter 3 | The heat pump design...
  • Page 14: Pipe Connections General

    Pipe installation must be carried out in accordance with pumps and control system with possibility of additional current standards and directives. F1355 can operate with heat. F1355 is connected to the brine and heating medi- a return temperature of up to 58 °C and an outgoing um circuits.
  • Page 15: Dimensions And Pipe Connections

    G2 (XL2) Heating medium re- internal thread G1 1/2 turn external thread G2 (XL6) Brine in internal thread G1 1/2 external thread G2 (XL7) Brine out internal thread G1 1/2 external thread G2 NIBE F1355 Chapter 4 | Pipe connections...
  • Page 16: Brine Side

    PEM-hose 40x2.4 PN 6.3) is used as a guide value. Caution Because the temperature of the brine system varies depending on the heat source, the 5.1.7 “br pmp al set.” menu must be set to a suitable value. Chapter 4 | Pipe connections NIBE F1355...
  • Page 17: Heating Medium Side

    The brine side must be pressurised to at least 0.05 MPa A climate system is a system that regulates indoor com- (0.5 bar). fort with the help of the control system in F1355 and for The pressure expansion vessel should be dimensioned example radiators, underfloor heating/cooling, fan as set out in the following diagram, to prevent malfunc- convectors etc.
  • Page 18: Water Heater

    Water heater Docking alternatives F1355 can be connected in several different ways. Ex- Connecting the hot water heater amples are shown below. Any docked hot water heater must be fitted with ne- ■ Further information about the options is available at cessary set of valves.
  • Page 19 Example - F1355 28 kW docked with electric additional heat and hot water heater (floating condensing) -EB1 -FL10 -EB1 -EB100-BT25 -EB100-GP10 -QM42 -RM21 -EB100-BT71 -QM43 -RN11 -EB100-BT1 -BP6 -QM21 -FL3 -CM3 -QM33 -EB100 -CP10 -XL28 -XL27 -QZ3 -EP15 -RM13 -QM57...
  • Page 20: Electrical Connections

    ■ the house wiring. If the building is equipped with an earth-fault breaker, ■ each F1355 should be equipped with a separate one. EP15 If a miniature circuit breaker is used this should have ■ at least motor characteristic “C”. See page 38 for fuse size.
  • Page 21 Power connection Connecting external operating voltage for the control system F1355 must be installed with a disconnect option on the supply cable. Minimum cable area must be sized accord- ing to the fuse rating used. Supplied cable for incoming NOTE supply electricity is connected to terminal block X1.
  • Page 22 Temperature sensor, hot water top A temperature sensor for hot water top (BT7) can be AA3-X6 connected to F1355 for showing the water temperature at the top of the tank (if possible). 16 17 18 Connect the sensor to terminal block AA3-X6:15 and AA3-X6:16.
  • Page 23: Optional Connections

    F1345 is operating, there is a risk of the property's main fuse F1355 tripping. F1355 has integrated load monitors that control Externt External the power steps for the electric additional heat by redis-...
  • Page 24 2. Option of changing the room temperature in °C. External step-controlled additional heat can be con- 3. Makes it possible to change/stabilise the room trolled by up to three potential-free relays in F1355 (3 temperature. step linear or 7 step binary). With the AXC 50 accessory,...
  • Page 25 The connection requires that the boiler sensor (BT52) is Additional heat in tank is activated in menu 5.1.12. connected to one of the AUX inputs in F1355, see section To control switching the additional heat on and off in “External connection options (AUX)” on page 27. The the tank, connect it to terminal block AA101-X7:4.
  • Page 26 Relay output for emergency mode Reversing valves F1355 can be supplemented with an external reversing NOTE valve (QN10) for hot water control (see page 35 for ac- cessory). Mark up any junction boxes with warnings for external voltage. Connect the external reversing valve (QN10) to terminal block AA101-X6:3 (N), AA101-X6:2 (operation) and AA101-X6:1 (L) as illustrated.
  • Page 27 An extra temperature sensor must be connected to connected to one of five AUXinputs, where the function F1355, in order to determine when it is time to switch for the connection must be determined in the heat pump between heating and cooling operation.
  • Page 28 A closed switch means that the brine pump is active. ■ Contact for activation of “temporary lux" An external switch function can be connected to F1355 for activation of the hot water function "temporary lux". The switch must be potential-free and connected to the selected input (menu 5.4).
  • Page 29 AA101-X9 at the same time that indication of the common alarm is activated (see page 35). An external contact function can be connected to F1355 for activation of one of the four fan speeds. The switch must be potential-free and connected to the AA101-X9 selected input (menu 5.4).
  • Page 30: Connecting Accessories

    (230 V AC) in total. Connecting accessories Instructions for connecting accessories are in the install- ation instructions provided for the respective accessory. See information at www.nibe.eu for the list of the ac- cessories that can be used with F1355. Chapter 5 | Electrical connections...
  • Page 31: Commissioning And Adjusting

    Check the miniature circuit-breaker. It may have components. tripped during transport. NOTE Do not start F1355 if there is a risk that the water in the system has frozen. Filling and venting Filling and venting the climate system Filling 1.
  • Page 32: Start Guide

    There must be water in the climate system be- fore the switch is set to " ". 1. Set switch (SF1) on F1355 to position " ". 2. Follow the instructions in the display's start guide. If the start guide does not start when you start the F1355, start it manually in menu 5.7.
  • Page 33: Post Adjustment And Venting

    Brine side ferential in menu 5.1.14 are used. If necessary, the max- F1355 has brine pumps that operate at a fixed speed. imum speed of the circulation pump can be limited in To ensure the correct flow in the brine system, the brine menu 5.1.11.
  • Page 34 When the room temperature is too low, increase ■ "temperature" (offset heating curve) in menu 1.1.1 by one increment. When the room temperature is too high, reduce ■ "temperature" (offset heating curve) in menu 1.1.1 by one increment. Chapter 6 | Commissioning and adjusting NIBE F1355...
  • Page 35: Accessories

    Energy measurement kit EMK 500 (one per water pump or external circulation pump is to be connected cooling module) to F1355 at the same time as the indication of common This accessory is installed externally and used to measure alarm is activated.
  • Page 36 Level monitor NV 10 Level monitor for extended checks of the brine level. Part no. 089 315 Pool heating POOL 40 POOL 40 is used to enable pool heating with F1355. Max. 17 kW. Part no 067 062 Room sensorRTS 40 This accessory is used to obtain a more even indoor temper- ature.
  • Page 37: Technical Data

    8 Technical data Dimensions and setting-out coordinates 80 145 NIBE F1355 Chapter 8 | Technical data...
  • Page 38: Technical Specifications

    0.15 (1.5 bar) / 0.07 (0.7 bar) Cut-out value, pressure transmitter LP 0.13 (1.3 bar) Difference, pressure transmitter LP 0.01 (0.1 bar) Brine circuit Max system pressure brine 0.6 (6 bar) Nominal flow 1.19 Chapter 8 | Technical data NIBE F1355...
  • Page 39 1,800 Required ceiling height 1,950 Weight complete heat pump Weight only cooling module EP14 / EP15 125 / 130 Part no., 3x400V 065 436 With feet removed, the height is approx. 1930 mm. NIBE F1355 Chapter 8 | Technical data...
  • Page 40 Köldbärare in, temperatur Framledning Framledning Framledning Flow pipe Framledning Flow pipe Return pipe Returledning Returledning Returledning Return pipe Returledning Arbetsområde över 75% för F1155-1255 6 kW. Vattentemperatur °C °C Köldbärare in, temperatur Framledning Returledning Chapter 8 | Technical data NIBE F1355...
  • Page 41: Energy Labelling

    The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to the package, the overall efficiency of the package should be recalculated. NIBE F1355 Chapter 8 | Technical data...
  • Page 42 Nominal heating medium flow Annual energy consumption 14,621 Brine flow brine-water or water-water heat 3.40 pumps Contact information NIBE Energy Systems – Box 14 – Hannabadsvägen 5 – 285 21 Markaryd – Sweden Chapter 8 | Technical data NIBE F1355...
  • Page 43: Electrical Wiring Diagram, 3X400V 28 Kw

    Electrical wiring diagram, 3x400V 28 kW NIBE F1355 Chapter 8 | Technical data...
  • Page 44 Chapter 8 | Technical data NIBE F1355...
  • Page 45 NIBE F1355 Chapter 8 | Technical data...
  • Page 46 Chapter 8 | Technical data NIBE F1355...
  • Page 47 NIBE F1355 Chapter 8 | Technical data...
  • Page 48 Chapter 8 | Technical data NIBE F1355...
  • Page 49 NIBE F1355 Chapter 8 | Technical data...
  • Page 50 Chapter 8 | Technical data NIBE F1355...
  • Page 51 NIBE F1355 Chapter 8 | Technical data...
  • Page 52: Item Register

    External connection options General, 14 Contact for activation of fan speed, 29 Heating medium side, 17 Contact for activation of “external adjustment", 29 Hot water heater, 18 Contact for activation of “temporary lux", 28 Chapter 9 | Item register NIBE F1355...
  • Page 53 Safety information, 4 Inspection of the installation, 7 Marking, 4 Safety precautions, 5 Serial number, 6 Symbols, 4 Symbols on F1355, 4 Safety precautions, 5 Serial number, 6 Shunt controlled additional heat, 25 Start guide, 32 Step controlled additional heat, 24 Supplied components, 10 Switch for "Smart Grid ready", 28...
  • Page 55: Contact Information

    Tel: +7 831 419 57 06 E-mail: kuzmin@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46 (0)433 73 000 E-mail: info@nibe.se www.nibe.se For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information.
  • Page 56 WS name: -Gemensamt WS version: a432 WS release date: 2017-10-12 13:02 Publish date: 2017-12-04 08:34 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 331996...