Download Print this page

Beretta Mynute Green E 25 C.S.I. Installer And User Manual page 23

Hide thumbs Also See for Mynute Green E 25 C.S.I.:

Advertisement

Available languages

Available languages

Mynute Green E 25 C.S.I.
Seasonal ambient heating
energy efficiency class
Parameter
Nominal output
For boilers for ambient heating and combined: Useful heat output
At nominal heat output and at
high temperature operation (*)
At 30% of the nominal
heat output and at low
temperature operation (**)
Auxiliaries electrical consumption
At full load
At partial load
In Standby mode
For combined heating appliances
Declared load profile
Daily electrical energy
consumption
Annual electrical energy
consumption
(*) High temperature operation: 60°C at boiler return line and 80°C at boiler delivery line.
(**) Low temperature operation: For condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C return line
temperature.
Mynute Green E 30 C.S.I.
Seasonal ambient heating
energy efficiency class
Parameter
Nominal output
For boilers for ambient heating and combined: Useful heat output
At nominal heat output and at
high temperature operation (*)
At 30% of the nominal
heat output and at low
temperature operation (**)
Auxiliaries electrical consumption
At full load
At partial load
In Standby mode
For combined heating appliances
Declared load profile
Daily electrical energy
consumption
Annual electrical energy
consumption
(*) High temperature operation: 60°C at boiler return line and 80°C at boiler delivery line.
(**) Low temperature operation: For condensing boilers 30°C, for low temperature boilers 37°C, for other heating appliances 50°C return line
temperature.
A
Symbol
Value
Unit
Pnominale
20
kW
P4
19.6
kW
P1
6.6
kW
elmax
28.0
elmin
10.1
PSB
2.4
XL
Qelec
0.183
kWh
AEC
40
kWh
A
Symbol
Value
Unit
Pnominale
24
kW
P4
24.5
kW
P1
8.2
kW
elmax
37.0
elmin
12.8
PSB
2.4
XL
Qelec
0.183
kWh
AEC
40
kWh
Water heating energy efficiency class
Parameter
Seasonal ambient heating
energy efficiency
For boilers for ambient heating and combined: efficiency
At nominal heat output and at
high temperature operation (*)
At 30% of the nominal
heat output and at low
temperature operation (**)
Other parameters
W
Heat loss in standby mode
W
Pilot flame energy consumption
W
Annual energy consumption
Internal sound output level
Nitric oxide emissions
Heating water energy efficiency
Daily fuel consumption
Annual fuel consumption
Water heating energy efficiency class
Parameter
Seasonal ambient heating
energy efficiency
For boilers for ambient heating and combined: efficiency
At nominal heat output and at
high temperature operation (*)
At 30% of the nominal
heat output and at low
temperature operation (**)
Other parameters
W
Heat loss in standby mode
W
Pilot flame energy consumption
W
Annual energy consumption
Internal sound output level
Nitric oxide emissions
Heating water energy efficiency
Daily fuel consumption
Annual fuel consumption
Mynute Green E C.S.I.
A
Symbol
Value
Unit
ηs
94
%
η4
88.4
%
η1
98,7
%
Pstby
45.0
W
Pign
-
W
QHE
60
GJ
LWA
49
dB
NOx
26
mg/kWh
ηwh
85
%
Qfuel
22.687
kWh
AFC
17
GJ
A
Symbol
Value
Unit
ηs
94
%
η4
88.2
%
η1
98,7
%
Pstby
45.0
W
Pign
-
W
QHE
75
GJ
LWA
51
dB
NOx
24
mg/kWh
ηwh
85
%
Qfuel
22.893
kWh
AFC
17
GJ
23

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Mynute green e 30 c.s.i.