The performance, indicated by the LEDs (B) and (C) is always visible
during normal operation of the circulator whereas the settings can be
carried out by pressing the button (A) (fig. 49).
Operating status indication
When the circulator is in operation the LED (B) is green (fig. 49). The
four yellow LEDs (C) indicate the electrical energy consumption (P1)
as shown in the following table
LED status
CIRCULATOR status
Green LED on +
Operating at minimum
1 yellow LED on
Green LED on +
2 yellow LEDs on
Green LED on +
Operating at medium-
3 yellow LEDs on
Green LED on +
Operating at maximum
4 yellow LEDs on
(*) For the power (P1) absorbed by the circulator see the indications
in the "Technical Data" table.
Modulation area
500
600
700
800
900
1000
1100
Modulation area
600
700
800
900
1000
1100
1200
Consumption in
% of MAX P1 (*)
0~25
Operating at
25~50
minimum-medium
50~75
maximum
500
450
400
350
300
250
200
150
100
50
0
1200
1300
0
100
400
350
300
250
200
150
100
50
0
1300
1400
0
100
Alarm status indication
If the circulator has detected one or more alarms the two-coloured
LED (B) will be red (fig. 49). The four yellow LEDs (C) indicate the
type of alarm as shown in the following table.
LED status
Red LED on +
1 yellow LED
on (LED 5)
Red LED on +
1 yellow LED
on (LED 4)
Red LED on +
1 yellow LED
100
on (LED 3)
If there are several alarms the circulator will display only the
alarm with the highest priority.
Display of active settings
With the circulator powered, press briefly on the button (A) to view
the active configuration of the circulator (fig. 49). The LEDs indicate
the active settings.
In this phase no variations can be made to the circulator configura-
tion. Two seconds after the button (A) has been pressed the user
interface returns to the normal operating status display.
5 METRES DISCHARGE HEAD
Modulation area
200
300
400
500
600
700
System capacity [l/h]
4 METRES DISCHARGE HEAD
Modulation area
200
300
400
500
600
700
System capacity [l/h]
ALARM
Status
description
CIRCULATOR
Start attempt
The drive shaft
every 1.5
is jammed
seconds
Warning only.
Low input
The circulator
voltage
continues to
operate
Electrical power
The circulator
supply fault or
is stopped
faulty circulator
Mynute Green E C.S.I.
800
900
1000
1100
1200
800
900
1000
1100
Possible
SOLUTION
Wait or unjam
the drive shaft
Check the
input voltage
Check the
electrical
power supply
or replace the
circulator