1.3.3 Mechanical Dimensions

A template for drilling can be found on the flap of the
packaging.
B
Ø 7mm
b
C
a A
M5
Illustration 1.1 Mechanical Dimensions.
Power (kW)
Frame
1 X 200-240V
3 X 200 -240V
M1
0.18 - 0.75
0.25 - 0.75
M2
1.5
1.5
M3
2.2
2.2 -3.7
M4
M5
1)
For LCP with potentiometer, please add 7.6mm.
Table 1.1 Mechanical Dimensions

1.3.4 Electrical Installation in General

NOTE
All cabling must comply with national and local regulations on cable cross-sections and ambient temperature. Copper
conductors required, (60-75° C) recommended.
Power (kW)
Frame
1 x 200-240V
3 x 200-240V
M1
0.18 - 0.75
0.25 - 0.75
M2
1.5
1.5
M3
2.2
2.2 - 3.7
M4
M5
1)
Spade connectors (6.3mm Faston plugs)
Table 1.2 Tightening of Terminals
VLT Micro Drive Quick Guide
B
Ø 7mm
b
C
C
a A
M4
Height (mm)
A (incl. decoupling
3 X 380-480V
A
plate)
0.37 - 0.75
150
1.5 - 2.2
176
3.0 - 7.5
239
11.0-15.0
292
347.5
18.5-22.0
335
387.5
3 x 380-480V
Line
Motor
0.37 - 0.75
1.4
0.7
1.5 - 2.2
1.4
0.7
3.0 - 7.5
1.4
0.7
11.0-15.0
1.3
1.3
18.5-22.0
1.3
1.3
®
MG.02.B6.02 - VLT
is a registered Danfoss trademark
B
B
Ø 5.5mm
b
b
C
a A
M2
M3
Width (mm)
a
B
205
140.4
70
230
166.4
75
294
226
90
272.4
125
315
165
Torque (Nm)
DC connection/Brake
Control Terminals
Spade
1)
1)
Spade
1)
Spade
1.3
1.3
B
Ø 4.5mm
Ø 4.5mm
b
C
a A
a A
M1
1)
(mm) Max. Weight
Depth
b
C
Kg
55
148
1.1
59
168
1.6
69
194
3.0
97
241
6.0
140
248
9.5
Earth
Relay
0.15
3
0.5
0.15
3
0.5
0.15
3
0.5
0.15
3
0.5
0.15
3
0.5
1
1
3

Hide quick links: