Samsung MIM-E03 series Installation Manual page 16

Control kit
Hide thumbs Also See for MIM-E03 series:
Table of Contents

Advertisement

Booster heater
Booster heater
Recommended wire specification
Load
Use Booster Heater (Max. 3kW)
❈ Code designation IEC: 60245 IEC 57/ CENELEC: H05RN-F
Connecting a booster heater (PTC heater – allowed limit : Max. 3kW)
1 . Directly connect a 'Booster heater' with 'A3 and A4 ' in TB-A .
• Wire spec : 6 . 0 mm
• Code designation IEC : 60245 IEC 57 / CENELEC : H05RN-F
NOTE
Specification table
Terminal Block (output)
Connection load
Output (A3, A4)
EHS Control unit_MIM-E03@_IM_E_34413-2.indd 15
Power Supply
1Ø, 220-240V, 50Hz
2
(regardless of distance)
Part
Power Cable
Max. Length
mm
, wires
m
2
4 . 0 / 3
L < 10m
6 . 0 / 3
10m < L
Specification
A3, A4 of TB-A
Direct connection a booster heater
AC 230V (MAX 20A)
15
2012-04-05 오후 1:20:01